Reduction of matrix effects through a simplified QuEChERS method and using small injection volumes in a LC-MS/MS system for the determination of 28 pesticides in fruits and vegetables
- 9 June 2016
- journal article
- research article
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 8 (25) , 5061-5069
Abstract
A simplified QuEChERS method coupled with a small injection volume was developed for the simultaneous determination of 28 pesticides in 6 matrices (apples, cucumbers, tomatoes, luffa, cabbages, and eggplants) using LC-MS/MS. In the sample procedure, acetonitrile with 0.1% (v/v) formic acid was used to extract and no depurative powder was used. Three fortified levels (10, 50, and 100 μg kg−1) were determined and the recoveries of 168 analyte/matrix combinations were in the range of 60–120% except for cyromazin, pendimethalin, and fenpropathrin. Half of the 168 LOQs were below 0.1 μg kg−1, and 29 LOQs were above 1 μg kg−1. Moreover, four relationships between signal suppression and injection volume were observed ranging from 0.5 μL to 15 μL. For many analyte/matrix combinations, the matrix effects could be reduced to less than 20% if the injection volume was less than a critical value (named critical volume). The critical volume depending on the initial extent of matrix effects was explored and the conclusion was: for weak or medium MEs, usually ≤2 μL injection volume was needed and for several weak MEs, injection volume ≤ 5 μL can reduce the matrix effect to a negligible level.Keywords
This publication has 32 references indexed in Scilit:
- Multiresidue Analysis of Multiclass Pesticides in Lavandin Essential Oil by LC/MS/MS Using the Scheduled Selected Reaction Monitoring ModeAnalytical Chemistry, 2010
- A novel strategy for reducing phospholipids-based matrix effect in LC–ESI-MS bioanalysis by means of HybridSPEJournal of Pharmaceutical and Biomedical Analysis, 2009
- Combating matrix effects in LC/ESI/MS: The extrapolative dilution approachAnalytica Chimica Acta, 2009
- High-Throughput Pesticide Residue Quantitative Analysis Achieved by Tandem Mass Spectrometry with Automated Flow InjectionAnalytical Chemistry, 2009
- Validation and uncertainty study of a comprehensive list of 160 pesticide residues in multi-class vegetables by liquid chromatography–tandem mass spectrometryJournal of Chromatography A, 2008
- Rapid determination of phenoxy acid residues in rice by modified QuEChERS extraction and liquid chromatography–tandem mass spectrometryAnalytica Chimica Acta, 2008
- Ruggedness testing of quantitative atmospheric pressure ionization mass spectrometry methods: the effect of co‐injected matrix on matrix effectsRapid Communications in Mass Spectrometry, 2007
- Matrix effects: the Achilles heel of quantitative high-performance liquid chromatography–electrospray–tandem mass spectrometryClinical Biochemistry, 2005
- The ion suppression phenomenon in liquid chromatography–mass spectrometry and its consequences in the field of residue analysisAnalytica Chimica Acta, 2005
- Postcolumn Introduction of an Internal Standard for Quantitative LC−MS AnalysisAnalytical Chemistry, 1999