Efficiency and sensitivity of the digital droplet PCR for the quantification of antibiotic resistance genes in soils and organic residues
Authors:
- 14 November 2016
- journal article
- research article
- Published by Springer Nature in Applied Microbiology and Biotechnology
- Vol. 100 (24) , 10597-10608
Abstract
Droplet digital PCR (ddPCR) allows absolute quantification and tolerance to inhibitors and has been proposed as the method of choice to overcome limitations of qPCR. The aim of this study was to evaluate ddPCR and qPCR performances to detect low copy number and copy number variation of antibiotic resistance genes (sul1 and qnrB genes encoding for resistance to sulfonamides and quinolones, respectively) using bacterial genomic DNA (gDNA) and metagenomic DNA extracted from soil and organic residue samples. With gDNA, qPCR showed a better range of quantification but the lower limit of quantification was at 15 copies of qnrB target vs. 1.6 in ddPCR. In the presence of background DNA or inhibitors, we observed a high loss of sensitivity in qPCR and an overestimation of target sequences. When using high amount of environmental DNA templates (70 ng per reaction), ddPCR was still allowing accurate quantification without adding PCR facilitator (i.e., T4 Gene 32 protein). Sensitivity to detect copy number variation was tenfold higher in ddPCR than in qPCR. Finally, the advantages of using ddPCR in environmental studies were confirmed with the quantification of sul1 and qnrB in soils, manures, or urban wastes.Keywords
Funding Information
- ADEME
- CNRS
- Campus France
- Département Soutien et Formation, Institut de Recherche pour le Développement (FR)
This publication has 34 references indexed in Scilit:
- Distribution, Activities, and Interactions of Methanogens and Sulfate-Reducing Prokaryotes in the Florida EvergladesApplied and Environmental Microbiology, 2015
- Droplet digital PCR for simultaneous quantification of general and human-associated fecal indicators for water quality assessmentWater Research, 2015
- Evaluation of droplet digital PCR for characterizing plasmid reference material used for quantifying ammonia oxidizers and denitrifiersAnalytical and Bioanalytical Chemistry, 2014
- Detection and enumeration of Pseudomonas aeruginosa in soil and manure assessed by an ecfX qPCR assayJournal of Applied Microbiology, 2013
- Comparison of Droplet Digital PCR to Real-Time PCR for Quantitative Detection of CytomegalovirusJournal of Clinical Microbiology, 2013
- High-resolution melting analysis for rapid characterization of qnr alleles in clinical isolates and detection of two novel alleles, qnrB25 and qnrB42Journal of Antimicrobial Chemotherapy, 2012
- Detection of pathogens in water: from phylochips to qPCR to pyrosequencingCurrent Opinion in Biotechnology, 2012
- Antibiotic resistance gene spread due to manure application on agricultural fieldsCurrent Opinion in Microbiology, 2011
- A comparison of the effects of PCR inhibition in quantitative PCR and forensic STR analysisElectrophoresis, 2011
- OXA-24, a Novel Class D β-Lactamase with Carbapenemase Activity in an Acinetobacter baumannii Clinical StrainAntimicrobial Agents and Chemotherapy, 2000