Patient satisfaction and wait times following outpatient manual vacuum aspiration compared to electric vacuum aspiration in the operating room: a cross-sectional study
Open Access
- 7 June 2017
- journal article
- Published by Springer Nature in Contraception and Reproductive Medicine
- Vol. 2 (1) , 18
Abstract
Outpatient manual vacuum aspiration (MVA) is a safe and equally effective alternative to electric vacuum aspiration (EVA) in the operating room. This project was conducted to determine whether outpatient MVA expedites care while maintaining patient satisfaction. A cross-sectional study of a convenience sample of patients undergoing surgical management of spontaneous abortion, induced abortion, or retained products of conception with either outpatient MVA under local anesthesia or EVA in the operating room was conducted. Of 138 women completing surveys, 48 (34.8%) underwent outpatient MVA and 90 (65.2%) underwent EVA in the operating room. Procedure length, time from decision to procedure, and patient satisfaction were assessed through a self-administered questionnaire completed post-procedure. Most (77%) patients in the MVA group reported waiting fewer than 2 h from the time of their decision to the procedure, while most (74%) EVA patients reported waiting over 12 h (P < 0.001); the MVA group reported higher satisfaction with time to procedure (P = 0.02). The median procedure length was significantly shorter in the EVA group (10 vs. 20 min, P < 0.001). There was no significant difference between groups in overall satisfaction with the procedure (P = 0.16). Outpatient MVA under local anesthesia is a suitable alternative to operating room-based EVA for management of spontaneous abortion, induced abortion, and retained products of conception. Outpatient MVA is associated with shorter decision-to-procedure time and is highly acceptable to patients. Integration of outpatient MVA into clinical settings can add time- and resource-saving options for uterine evacuation while maintaining a positive patient experience.Keywords
This publication has 15 references indexed in Scilit:
- Abortion Incidence and Service Availability In the United States, 2011Perspectives on Sexual and Reproductive Health, 2014
- First-trimester surgical abortion practices: a survey of National Abortion Federation membersContraception, 2009
- Decreased waiting periods in a public pregnancy termination clinicContraception, 2008
- Patient Preferences, Satisfaction, and Resource Use in Office Evacuation of Early Pregnancy FailureObstetrics & Gynecology, 2006
- Manual Versus Electric Vacuum Aspiration for Early First-Trimester Abortion: A Controlled Study of Complication RatesObstetrics & Gynecology, 2004
- Acceptability of manual versus electric aspiration for first trimester abortion: a randomized trialContraception, 2003
- Similarities in women’s perceptions and acceptability of manual vacuum aspiration and electric vacuum aspiration for first trimester abortionContraception, 2003
- Comparison of pain and time of procedures with two first-trimester abortion techniques performed by residents and facultyAmerican Journal of Obstetrics and Gynecology, 2001
- VERY EARLY ABORTION USING SYRINGE AS VACUUM SOURCEThe Lancet, 1972
- ABORTION INDUCED BY MEANS OF UTERINE ASPIRATOR1967