Usability and Training Differences Between Two Personal Insulin Pumps
- 14 October 2014
- journal article
- research article
- Published by SAGE Publications in Journal of Diabetes Science and Technology
- Vol. 9 (2) , 221-230
Abstract
Background: The purpose of this study was to determine if there were usability and training differences between the Medtronic MiniMed Paradigm Revel™ Insulin Pump and the Tandem Diabetes Care t:slim® Insulin Pump during use by representative users, performing representative tasks, in a simulated use environment. Methods: This study utilized a between-subjects experimental design with a total of 72 participants from 5 sites across the United States. Study participants were randomized to either the Revel pump group or the t:slim Pump group. Participants were 18 years of age or older and managed their diabetes using multiple daily insulin injections. Dependent variables included training time, training satisfaction, time on task, task failures, System Usability Scale (SUS) ratings, perceived task difficulty, and a pump survey that measured different aspects of the pumps and training sessions. Results: There was a statistically significant difference in training times and error rates between the t:slim and Revel groups. The training time difference represented a 27% reduction in time to train on the t:slim versus the Revel pump. There was a 65% reduction in participants’ use error rates between the t:slim and the Revel group. The t:slim Pump had statistically significant training and usability advantages over the Revel pump. Conclusions: The reduction in training time may have been a result of an optimized information architecture, an intuitive navigational layout, and an easy-to-read screen. The reduction in use errors with the t:slim may have been a result of dynamic error handling and active confirmation screens, which may have prevented programming errors.Keywords
This publication has 13 references indexed in Scilit:
- Human Factors Research Applied: The Development of a Personal Touch Screen Insulin Pump and Users' Perceptions of Actual UseDiabetes Technology & Therapeutics, 2013
- Though costly, insulin pens facilitate better adherence.2013
- The Role of Human Factors in the Design and Development of an Insulin PumpJournal of Diabetes Science and Technology, 2012
- Projection of the year 2050 burden of diabetes in the US adult population: dynamic modeling of incidence, mortality, and prediabetes prevalencePopulation Health Metrics, 2010
- Nutritionist Visits, Diabetes Classes, and Hospitalization Rates and ChargesDiabetes Care, 2008
- How to achieve good compliance with inhaled asthma therapyRespiratory Medicine, 2004
- Patient Safety, Potential Adverse Drug Events, and Medical Device Design: A Human Factors Engineering ApproachJournal of Biomedical Informatics, 2001
- Analysis of a “Simple” Medical DeviceErgonomics in Design: The Quarterly of Human Factors Applications, 2001
- Improving patient compliance with asthma therapyRespiratory Medicine, 2000
- Reducing errors in medicineBMJ, 1999