Simultaneous nitritation and denitritation of domestic wastewater without addition of external carbon sources at limited aeration and normal temperatures

Authors:
  • WZWei Zheng
    Wei Zheng
  • YZYue Zhang
    Yue Zhang
  • LLLei Li
    Lei Li
  • YPYongzhen Pen
    Yongzhen Pen
  • SWShuying Wang
    Shuying Wang

Abstract
Nitrogen removal via nitrite and simultaneous nitrification-denitrification (SND) are two processes for nitrogen removal from wastewater. The combination of these two processes, i.e., simultaneous nitritation-denitritation or SND via nitrite, is highly beneficial for the domestic wastewater treatment in terms of lower carbon requirements, reduced oxygen demand and less biomass production. A lab-scale sequencing batch reactor (SBR) treating domestic wastewater with low C/N ratios was operated to investigate simultaneous nitritation-denitritation without addition of external carbon sources under limiting aeration and normal temperatures (19±1°C). The results showed that at a longer sludge retention time (SRT) of 50–66 d and an average dissolved oxygen (DO) concentration of 0.65 mg/L, nitritation was successfully achieved with nitrite accumulation rate over 95%. Fluorescence in-situ hybridization (FISH) analysis proved that ammonia oxidizing bacteria (AOB) became dominant nitrifying bacteria. Furthermore, de...