Experimental Investigation of Single-Phase, Condensation, and Flow Boiling Heat Transfer for a Spirally Fluted Tube
Authors:
- 1 January 1992
- journal article
- research article
- Published by Taylor & Francis in Heat Transfer Engineering
- Vol. 13 (1) , 42-52
Abstract
A spirally fluted tube was tested in a vertically oriented shell-and-tube heat exchanger in both condensing and evaporating service. The heat exchanger showed substantial improvement in performance over that expected from a comparable exchanger with plain tubes. The condensation tests were run with working fluids of ammonia and R-114 condensing on the shell side of the heat exchanger. The boiling tests were run with R-11 boiling on the tube side in upward forced convection; heat was supplied by steam condensing on the shell side.Keywords
This publication has 4 references indexed in Scilit:
- ANALYSIS OF NUSSELT-TYPE CONDENSATION ON A VERTICAL FLUTED SURFACENumerical Heat Transfer, 1980
- Boiling Heat Transfer and Pressure Drop in Internal Spiral-Grooved TubesBulletin of JSME, 1979
- LAMINAR FILMWISE CONDENSATION ON A VERTICAL SINGLE FLUTED PLATE1978
- Enhancement of film condensation rate on vertical tubes by longitudinal finsAIChE Journal, 1968