Doppler broadening of energy spectra in Compton cameras
Authors:
- A. BolozdynyaABA. Bolozdynya
- W. ChangWCW. Chang
- 23 November 2002
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2 (10823654) , 1361-1365
Abstract
Compton cameras utilize the Compton effect to achieve directional localization of gamma rays. The accuracy of the localization depends, in part, on the uncertainties in the measurement of energies. These uncertainties have conventionally been assumed to be due to the effects of finite detector energy resolution alone. There is another source of energy uncertainty that none of the Compton cameras proposed or built thus far accounts for the Doppler broadening of energy spectra that arises from the Compton interaction between gamma rays and moving electrons bound to atoms. The authors have used Monte Carlo simulations and direct calculations to demonstrate that the energy uncertainties due to Doppler broadening are non-negligible. For low-energy gamma rays, these uncertainties are generally more significant than those due to the finite energy resolutions of semiconductor detectors (for example, germanium and silicon). Expressions for estimating the angular uncertainties in Compton cameras due to energy resolution and Doppler broadening are derived. The authors conclude that the accuracy of the calculation of the scatter angle can be improved if the electron pre-collision momentum is known. However, even without such knowledge. Compton cameras still have the potential to achieve spatial resolutions that are comparable to those of mechanically collimated systems.Keywords
This publication has 13 references indexed in Scilit:
- A novel Compton scatter camera design for in-vivo medical imaging of radiopharmaceuticals2002
- A high sensitivity, electronically collimated gamma cameraIEEE Transactions on Nuclear Science, 1997
- Monte Carlo calculation of point-spread functions of Compton scatter camerasIEEE Transactions on Nuclear Science, 1997
- A high pressure xenon self-triggered scintillation drift chamber with 3D sensitivity in the range of 20–140 keV deposited energyNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1997
- Implementation of the Doppler broadening of a Compton-scattered photon into the EGS4 codeNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1994
- A ring Compton scatter camera for imaging medium energy gamma raysIEEE Transactions on Nuclear Science, 1993
- Gamma ray imaging with silicon detectors — A Compton camera for radionuclide imaging in medicineNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1988
- An electronically collimated gamma camera for single photon emission computed tomography. Part II: Image reconstruction and preliminary experimental measurementsMedical Physics, 1983
- Relationship of the relativistic Compton cross section to the momentum distribution of bound electron statesPhysical Review B, 1975
- Hartree-Fock Compton profiles for the elementsAtomic Data and Nuclear Data Tables, 1975