Evaluation of changes in hemoglobin levels associated with ABO‐ incompatible plasma in apheresis platelets
Authors:
- K Benson Md DirectorKDK Benson Md Director
- 1 January 1998
- journal article
- case report
- Published by Wiley in Transfusion
- Vol. 38 (1) , 51-55
Abstract
BACKGROUND: Hemolytic transfusion reaction is considered a rare complication of platelet transfusion. If minor ABO incompatibility exists (donor antibody directed against recipient's red cells [plasma‐ incompatible platelets]), however, the antibodies present in the plasma of platelets may cause acute hemolysis. A retrospective study was performed to identify possible hemolysis related to the transfusion of plasma‐incompatible apheresis platelets. STUDY DESIGN AND METHODS: Acute hemolysis due to low‐titer anti‐A present in group O apheresis platelets transfused to a group A patient is reported. Pretransfusion and posttransfusion hemoglobin levels were evaluated in 16 non‐group O autologous bone marrow transplant patients receiving apheresis platelets. All patients received, within 24 hours, both ABO‐identical and plasma‐incompatible platelet transfusions. No red cells were transfused during the time between the collection of the pretransfusion and posttransfusion hemoglobin samples. RESULTS: A total of 24 evaluable paired platelet transfusions in the 16 patients were compared. The mean change in hemoglobin following transfusion of the ABO‐identical and plasma‐incompatible platelets was ‐0.50 g per dL and ‐ 0.11 g per dL, respectively (p = 0.193). CONCLUSION: There was no significant change in the hemoglobin concentration associated with the transfusion of plasma‐incompatible apheresis platelets (minor ABO incompatibility) in our study group. The case reported here represents the only hemolytic transfusion reaction identified among 46,176 platelet transfusions performed at this hospital, despite approximately 21 percent of all platelet transfusions being plasma incompatible. The risk of such a reaction remains low.Keywords
This publication has 8 references indexed in Scilit:
- Circulating immune complexes involving the ABO system after platelet transfusionBritish Journal of Haematology, 1993
- A Study of the Effect of AB0 Incompatible Plasma in Platelet Concentrates Transfused to Bone Marrow Transplant RecipientsVox Sanguinis, 1991
- ABO compatibility can influence the results of platelet transfusionTransfusion, 1989
- Hemolysis following platelet transfusions from ABO‐incompatible donorsTransfusion, 1985
- Haemolytic Transfusion Reaction Due to ABO Incompatible Plasma in a Platelet ConcentrateScandinavian Journal of Haematology, 1982
- ABO compatibility and platelet transfusions of alloimmunized thrombocytopenic patientsBlood, 1979
- Anti‐A1 in the Plasma of Platelet Concentrates Causing a Hemolytic ReactionTransfusion, 1977
- Effect of Anticoagulant and ABO Incompatibility on Recovery of Transfused Human PlateletsBlood, 1965