A finite size pencil beam algorithm for IMRT dose optimization: density corrections
Authors:
- U JeleńUJU Jeleń
- M AlberMAM Alber
- 10 January 2007
- journal article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 52 (3) , 617-633
Abstract
For beamlet-based IMRT optimization, fast and less accurate dose computation algorithms are frequently used, while more accurate algorithms are needed to recompute the final dose for verification. In order to speed up the optimization process and ensure close proximity between dose in optimization and verification, proper consideration of dose gradients and tissue inhomogeneity effects should be ensured at every stage of the optimization. Due to their speed, pencil beam algorithms are often used for precalculation of beamlet dose distributions in IMRT treatment planning systems. However, accounting for tissue heterogeneities with these models requires the use of approximate rescaling methods. Recently, a finite size pencil beam (fsPB) algorithm, based on a simple and small set of data, was proposed which was specifically designed for the purpose of dose pre-computation in beamlet-based IMRT. The present work describes the incorporation of 3D density corrections, based on Monte Carlo simulations in heterogeneous phantoms, into this method improving the algorithm accuracy in inhomogeneous geometries while keeping its original speed and simplicity of commissioning. The algorithm affords the full accuracy of 3D density corrections at every stage of the optimization, hence providing the means for density related fluence modulation like penumbra shaping at field edges.Keywords
This publication has 41 references indexed in Scilit:
- Comparison of dose calculation algorithms in phantoms with lung equivalent heterogeneities under conditions of lateral electronic disequilibriumMedical Physics, 2004
- A revision of the -evaluation concept for the comparison of dose distributionsPhysics in Medicine & Biology, 2003
- The impact of electron transport on the accuracy of computed doseMedical Physics, 2000
- Dose calculations for external photon beams in radiotherapyPhysics in Medicine & Biology, 1999
- Decomposition of pencil beam kernels for fast dose calculations in three‐dimensional treatment planningMedical Physics, 1993
- Experimental verification of a three-dimensional dose calculation algorithm using a specially designed heterogeneous phantomMedical Physics, 1993
- A finite‐size pencil beam model for photon dose calculations in three dimensionsMedical Physics, 1992
- Monte Carlo techniques in medical radiation physicsPhysics in Medicine & Biology, 1991
- Collapsed cone convolution of radiant energy for photon dose calculation in heterogeneous mediaMedical Physics, 1989
- A photon dose distribution model employing convolution calculationsMedical Physics, 1985