Radiation exposure in computed tomography
Authors:
- Denise BosDenise Bos
- Nika GuberinaNGNika Guberina
- Sebastian ZensenSZSebastian Zensen
- Marcel OpitzMOMarcel Opitz
- Michael ForstingMFMichael Forsting
- Axel WetterAWAxel Wetter
- 3 March 2023
- journal article
- review article
- Published by Deutscher Arzte-Verlag GmbH in Deutsches Ärzteblatt international
- Vol. 120 (9) , 135-+
Abstract
Computed tomography (CT) studies are requested by specialists from most medical disciplines and play a vital role in the diagnosis and treatment of patients. It follows that physicians of all specialties should possess basic knowledge of computed tomography, its proper use, and the radiation exposure associated with it. This review is based on publications retrieved by a selective search of the literature. Approximately 12 million CT studies are carried out in Germany each year, and the trend is rising. Approximately 9% of all diagnostic studies involving ionizing radiation are CT studies. On average, more than 60% of the collective effective dose due to medical radiation exposure is attributable to CT. There are two types of radiation effects caused by ionizing radiation: stochastic and deterministic. The additional, individual relative lifetime cancer mortality risk due to ionizing radiation with whole-body exposure at a low single dose is estimated at 5% per sievert. Radiation exposure from CT studies of the head and trunk, e.g. of a patient with polytrauma, corresponds to an additional lifetime cancer mortality risk of approximately 0.1% at an effective dose of approximately 20 millisievert. The radiation exposure due to CT, and the risks to which patients are subjected by it, have become more important with greater use of CT. Technical advances, targeted dose monitoring, and analyses of dose data can help identify areas where improvement is necessary, in furtherance of the overriding goal of lowering patients’ radiation exposure while preserving adequate image quality.Keywords
This publication has 19 references indexed in Scilit:
- Current CT practice in Germany: Results and implications of a nationwide surveyEuropean Journal of Radiology, 2017
- Radiation Dose Monitoring in the Clinical RoutineRöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren, 2016
- How Much Is the Dose Varying between Follow-Up CT-Examinations Performed on the Same Scanner with the Same Imaging Protocol?PLOS ONE, 2016
- Updated estimates of typical effective doses for common CT examinations in the UK following the 2011 national reviewBritish Journal of Radiology, 2016
- Clinical Implementation of the National Electrical Manufacturers Association CT Dose Check Standard at ACR Dose Index Registry SitesJournal of the American College of Radiology, 2014
- CT Dose Index and Patient Dose: They AreNotthe Same ThingRadiology, 2011
- Volume CT Dose Index and Dose-Length Product Displayed during CT: What Good Are They?Radiology, 2011
- In Defense of Body CTAmerican Journal of Roentgenology, 2009
- Spiral volumetric CT with single-breath-hold technique, continuous transport, and continuous scanner rotation.Radiology, 1990
- Computerized transverse axial scanning (tomography): Part 1. Description of systemBritish Journal of Radiology, 1973