Steady-state analysis of self-excited induction generators
Author:
- T.F. ChanTCT.F. Chan
- 1 June 1994
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Energy Conversion
- Vol. 9 (2) , 288-296
Abstract
Two solution techniques for the steady-state analysis of a self-excited induction generator (SEIG) are presented in this paper. The first technique employs a novel parameter elimination procedure to yield a 7th-degree polynomial in the per-unit frequency, numerical solution of which enables the performance of the SEIG to be determined. The second technique employs symbolic programming for the derivation and solution of the the high-order polynomial. The symbolic programming technique is further extended to the analysis of a voltage compensated SEIG using long-shunt connection. Very good agreement between experimental and computed results have been obtained on a 2 kW laboratory machine.Keywords
This publication has 5 references indexed in Scilit:
- Voltage compensation of an induction generator with long-shunt connectionIEEE Transactions on Energy Conversion, 1989
- Steady State Analysis and Performance of an Isolated Self-Excited Induction GeneratorIEEE Transactions on Energy Conversion, 1986
- Wind-driven self-excited pole-changing induction generatorsIEE Proceedings B Electric Power Applications, 1986
- Analysis of the Isolated Induction GeneratorIEEE Transactions on Power Apparatus and Systems, 1983
- Analysis of self-excited induction generatorsIEE Proceedings C Generation, Transmission and Distribution, 1982