Ultrasonic array images are adversely affected by errors in the assumed or measured imaging parameters. For non-destructive testing and evaluation, this can result in reduced defect detection and characterization performance. In this paper, an autofocus algorithm is presented for estimating and correcting imaging parameter errors using the collected echo data and a priori knowledge of the image geometry. Focusing is achieved by isolating a known geometric feature in the collected data and then performing a weighted least-squares minimization of the errors between the data and a feature model, with respect to the unknown parameters. The autofocus algorithm is described for the estimation of element positions in a flexible array coupled to a specimen with an unknown surface profile. Experimental results are shown using a prototype flexible array and it is demonstrated that (for an isolated feature and a well-prescribed feature model) the algorithm is capable of generating autofocused images that are comparable in quality to benchmark images generated using accurately known imaging parameters.Keywords
This publication has 25 references indexed in Scilit:
- The wavenumber algorithm for full-matrix imaging using an ultrasonic arrayIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 2008
- Overdetermined Least-Squares Aberration Estimates Using Common-Midpoint SignalsIEEE Transactions on Medical Imaging, 2004
- Adaptive multi-element synthetic aperture imaging with motion and phase aberration correctionIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 1998
- A speckle target adaptive imaging technique in the presence of distributed aberrationsIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 1997
- The combined effect of signal decorrelation and random noise on the variance of time delay estimationIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 1997
- Synthetic receive aperture imaging with phase correction for motion and for tissue inhomogeneities. II. Effects of and correction for motionIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 1992
- Phase-aberration correction using signals from point reflectors and diffuse scatterers: basic principlesIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 1988
- Improved Lower Bounds on Signal Parameter EstimationIEEE Transactions on Information Theory, 1975
- Estimation and correction of near-surface time anomaliesGeophysics, 1974
- AUTOMATED STATIC CORRECTIONS*Geophysical Prospecting, 1968