Synthesis, Characterization and Quantification of Simvastatin Metabolites and Impurities
Open Access
- 1 January 2011
- journal article
- Published by MDPI AG in Scientia Pharmaceutica
- Vol. 79 (3) , 601-614
Abstract
Simvastatin is used in treatment of hypercholesterolemia because it regulates cholesterol synthesis as a result of its β-hydroxy acid acting as an inhibitor of 3-hydroxy-methylglutaryl coenzyme A (HMG-CoA). The present communication deals with synthesis, characterization and development of accurate, precise and sensitive Reverse Phase High Performance Liquid Chromatography (RP-HPLC) method for simultaneous estimation of simvastatin and its synthetic impurities. The impurities methyl ether and β-hydroxy acid of simvastatin were synthesized in the laboratory and characterized by MS, NMR and FT-IR spectroscopy. The separation of simvastatin and its impurities was carried out on an isocratic JASCO RP-HPLC system using KYA TECH HIQ SIL C(18) column (150 × 4.6 mm internal diameter, particle size 5 μm) operating at ambient temperature using acetonitrile:water (80:20 v/v) with 0.1% orthophosphoric acid as mobile phase. The method developed for HPLC analysis of three impurities along with simvastatin was validated using ICH Q2B (R1) guidelines and it complied with these guidelines. The results of analysis were found to be in the range of 98.14% to 101.89% for all analytes with acceptable accuracy and precision. The method can be used for detection and quantification of synthetic impurities in bulk or formulations of simvastatin.Keywords
This publication has 11 references indexed in Scilit:
- An improved and fully validated LC–MS/MS method for the simultaneous quantification of simvastatin and simvastatin acid in human plasmaJournal of Pharmaceutical and Biomedical Analysis, 2008
- Structural elucidation of an unknown Simvastatin by-product in industrial synthesis starting from LovastatinJournal of Pharmaceutical and Biomedical Analysis, 2007
- Influence of structural and interfacial properties of microemulsion eluent on chromatographic separation of simvastatin and its impuritiesJournal of Chromatography A, 2006
- Application of a novel ultra-low elution volume 96-well solid-phase extraction method to the LC/MS/MS determination of simvastatin and simvastatin acid in human plasmaJournal of Pharmaceutical and Biomedical Analysis, 2005
- Identification of unknown impurities in simvastatin substance and tablets by liquid chromatography/tandem mass spectrometryJournal of Pharmaceutical and Biomedical Analysis, 2005
- Quantitative analysis of simvastatin and its β-hydroxy acid in human plasma using automated liquid–liquid extraction based on 96-well plate format and liquid chromatography-tandem mass spectrometryJournal of Pharmaceutical and Biomedical Analysis, 2004
- The use of hyphenated LC–MS technique for characterisation of impurity profiles during drug developmentJournal of Pharmaceutical and Biomedical Analysis, 1998
- Determination of simvastatin and its active metabolite in human plasma by column-switching high-performance liquid chromatography with fluorescence detection after derivatization with 1-bromoacetylpyreneJournal of Chromatography B: Biomedical Sciences and Applications, 1997
- Practical HPLC Method Development1997
- Simultaneous determination of simvastatin and its hydroxy acid form in human plasma by high-performance liquid chromatography with UV detectionJournal of Pharmaceutical and Biomedical Analysis, 1992