Intermittent Detection of Fetal Heart Rate Abnormalities Identify Infants at Greatest Risk for Fresh Stillbirths, Birth Asphyxia, Neonatal Resuscitation, and Early Neonatal Deaths in a Limited-Resource Setting: A Prospective Descriptive Observational Study at Haydom Lutheran Hospital
Authors:
- Hege Langli ErsdalHEHege Langli Ersdal
- Estomih MdumaEMEstomih Mduma
- Erling SvensenESErling Svensen
- Johanne SundbyJSJohanne Sundby
- Jeffrey PerlmanJPJeffrey Perlman
- 15 August 2012
- journal article
- research article
- Published by S. Karger AG in Neonatology
- Vol. 102 (3) , 235-242
Abstract
Background: Intermittent fetal heart rate (FHR) monitoring during labor using an acoustic stethoscope is the most frequent method for fetal assessment of well-being in low- and middle-income countries. Evidence concerning reliability and efficacy of this technique is almost nonexistent. Objectives: To determine the value of routine intermittent FHR monitoring during labor in the detection of FHR abnormalities, and the relationship of abnormalities to the subsequent fresh stillbirths (FSB), birth asphyxia (BA), need for neonatal face mask ventilation (FMV), and neonatal deaths within 24 h. Methods: This is a descriptive observational study in a delivery room from November 2009 through December 2011. Research assistants/observers (n = 14) prospectively observed every delivery and recorded labor information including FHR and interventions, neonatal information including responses in the delivery room, and fetal/neonatal outcomes (FSB, death within 24 h, admission neonatal area, or normal). Results: 10,271 infants were born. FHR was abnormal (i.e. 160 beats/min) in 279 fetuses (2.7%) and absent in 200 (1.9%). Postnatal outcomes included FSB in 159 (1.5%), need for FMV in 695 (6.8%), BA (i.e. 5-min Apgar score <7) in 69 (0.7%), and deaths in 89 (0.9%). Abnormal FHR was associated with labor complications (OR = 31.4; 95% CI: 23.1–42.8), increased need for FMV (OR = 7.8; 95% CI: 5.9–10.1), BA (OR = 21.7; 95% CI: 12.7–37.0), deaths (OR = 9.9; 95% CI: 5.6–17.5), and FSB (OR = 35; 95% CI: 20.3–60.4). An undetected FHR predicted FSB (OR = 1,983; 95% CI: 922–4,264). Conclusions: Intermittent detection of an absent or abnormal FHR using a fetal stethoscope is associated with FSB, increased need for neonatal resuscitation, BA, and neonatal death in a limited-resource setting. The likelihood of an abnormal FHR is magnified with labor complications.Keywords
This publication has 17 references indexed in Scilit:
- National, regional, and worldwide estimates of stillbirth rates in 2009 with trends since 1995: a systematic analysisThe Lancet, 2011
- Stillbirths: Where? When? Why? How to make the data count?The Lancet, 2011
- Countdown to 2015 decade report (2000–10): taking stock of maternal, newborn, and child survivalThe Lancet, 2010
- Global, regional, and national causes of child mortality in 2008: a systematic analysisThe Lancet, 2010
- Obstetric care in low-resource settings: What, who, and how to overcome challenges to scale up?International Journal of Gynecology & Obstetrics, 2009
- Two million intrapartum-related stillbirths and neonatal deaths: Where, why, and what can be done?International Journal of Gynecology & Obstetrics, 2009
- ACOG Practice Bulletin No. 106: Intrapartum Fetal Heart Rate Monitoring: Nomenclature, Interpretation, and General Management PrinciplesObstetrics & Gynecology, 2009
- Fetal Monitoring during LaborNeonatology, 2009
- Appropriate medical technology for perinatal care in low-resource countriesPaediatrics and International Child Health, 2008
- Randomised controlled trial of intrapartum fetal heart rate monitoringBMJ, 1994