Good results with an uncemented proximally HA-coated stem in hip revision surgery: 62 hips followed for 2–13 years
Authors:
- Olof G SköldenbergOSOlof G Sköldenberg
- Henrik S G BodénHBHenrik S G Bodén
- Torbjörn E AhlTATorbjörn E Ahl
- Per Y AdolphsonPAPer Y Adolphson
Open Access
- 1 January 2008
- journal article
- Published by Medical Journals Sweden AB in Acta Orthopaedica
- Vol. 79 (2) , 184-193
Abstract
Proximal bone loss due to stress-shielding is a matter of concern after uncemented femoral hip revision. We have used short, proximally hydroxyapatite-coated prostheses in revision since 1989, and we now report the results. 60 patients (62 hips) were revised because of aseptic loosening. Bone defects prior to revision were mostly of type II according to the Gustilo-Pasternak and Endo-Klinik classifications. Follow-up time was 73 (24-161) months. 9 patients had died before follow-up; 8 of these still had the stem in place. Clinical assessment was performed with the Harris hip score. Radiographs were evaluated for bone defects at revision, postoperative stem fixation, and periprosthetic bone remodeling. Mean Harris hip score was 75 (30-100) points. There was no stem loosening or progressive subsidence. 8 patients had mild to moderate thigh pain. Osteolysis, present at revision, had diminished, partially or completely, in four-fifths of the hips at follow-up. 4 hips had required re-revision due to fracture or dislocation. The 6-year prosthesis survival rate was 95% (95% CI: 0.83-0.98). Uncemented revision with a short, proximally hydroxyapatite-coated prosthesis is a reliable procedure with encouraging results in the medium term if bone defects at revision are moderate.Keywords
This publication has 35 references indexed in Scilit:
- Total hip arthroplasty with an uncemented hydroxyapatite-coated tapered titanium stem: results at a minimum of 10years’ follow-up in 104 hipsJournal of Orthopaedic Science, 2006
- The Use of a Hydroxyapatite-Coated Primary Stem in Revision Total Hip ArthroplastyThe Journal of Arthroplasty, 2006
- Hydroxyapatite-ceramic-coated femoral stems in revision hip surgeryThe Journal of Bone and Joint Surgery. British volume, 2005
- Revision of cemented hip arthroplasty using a hydroxyapatite-ceramic-coated femoral componentThe Journal of Bone and Joint Surgery. British volume, 2005
- Cementless Femoral Revision Arthroplasty of the HipClinical Orthopaedics and Related Research, 2001
- Treatment of isolated injuries of the lunotriquetral ligamentThe Journal of Bone and Joint Surgery. British volume, 2001
- Impaction bone-grafting of severely defective femora in revision total hip surgery: 21 hips followed for 41-85 monthsActa Orthopaedica, 2000
- Impaction bone grafting in revision hip surgeryThe Journal of Bone and Joint Surgery. British volume, 2000
- Uncemented Revision Total Hip ArthroplastyClinical Orthopaedics and Related Research, 1996
- Accuracy of migration analysis in hip arthroplasty Digitized and conventional radiography, compared to radiostereometry in 51 patientsActa Orthopaedica, 1995