Use of high-frequency chest wall oscillation therapy in infants: protocol for a feasibility randomised controlled clinical trial
Authors:
- Mayara Fabiana Pereira CostaMCMayara Fabiana Pereira Costa
- Gaby Kelly Bezerra de MacedoGMGaby Kelly Bezerra de Macedo
- Ana Tereza Do Nascimento Sales Figu FernandesAFAna Tereza Do Nascimento Sales Figu Fernandes
- Gentil Gomes da Fonseca FilhoGFGentil Gomes da Fonseca Filho
- Karolinne Souza MonteiroKMKarolinne Souza Monteiro
Open Access
- 5 January 2026
- journal article
- clinical trial-protocol
- Published by BMJ in BMJ Open Respiratory Research
- Vol. 13 (1) , e003505
Abstract
Introduction: Since the inflammatory response increases the production and accumulation of mucus in the airways during respiratory infections, conventional and unconventional techniques of secretion removal are used. High-frequency chest wall oscillation is an effective strategy for secretion removal; however, it presents barriers due to the high cost. In Brazil, the Expector was developed using a kangaroo-vest interface as an accessible alternative; however, studies are needed to evaluate the use of Expector in infants. The aim of this study was to assess the feasibility and usability of the Expector device in healthy infants. Methods and analysis: For this feasibility randomised controlled clinical trial, 30 participants aged 3–6 months will be divided into three groups. Two experimental groups will use the Expector device (kangaroo baby-carrier version) with different configurations of the minivibrating motors (ie, totally activated and upper half of motors activated). The device will be deactivated for the control group. The following parameters will be assessed before the test, every 5 min during 15 min of device use and for 15 min after its use: heart rate, respiratory rate, peripheral oxygen saturation, pulmonary auscultation, sleep/wakefulness state, pain and parental satisfaction. Data will be described using measures of central tendency and dispersion and absolute and relative frequencies. Statistical analysis will be performed using correlation and intra- and intergroup comparisons. This study will generate preliminary evidence regarding the feasibility of Expector (kangaroo baby-carrier version) for infants and allow randomised and controlled studies using this technology. Ethics and dissemination: The Ethics Committee of the Faculty of Health Sciences of Trairi of the Federal University of Rio Grande do Norte approved this study (Number 5636504). Findings will be disseminated through peer-reviewed journal publications, scientific conference presentations and knowledge translation to the public via social media. Trial registration number: This feasibility randomised controlled clinical trial was registered in the Brazilian Registry of Clinical Trials (REBEC) (Number RBR-5r8v8qz).Keywords
Funding Information
- Coordenação de Aperfeiçoamento de Pessoal de Nível Superior
This publication has 20 references indexed in Scilit:
- A comparison of high frequency chest wall oscillation and intrapulmonary percussive ventilation for airway clearance in pediatric patients with tracheostomyPostgraduate Medicine, 2016
- CONSORT 2010 statement: extension to randomised pilot and feasibility trialsBMJ, 2016
- Estimating the sample size for a pilot randomised trial to minimise the overall trial sample size for the external pilot and main trial for a continuous outcome variableStatistical Methods in Medical Research, 2015
- The global burden of respiratory disease-Impact on child healthPediatric Pulmonology, 2014
- Fundamentals of Lung AuscultationNew England Journal of Medicine, 2014
- How We Design Feasibility StudiesAmerican Journal of Preventive Medicine, 2009
- Cross‐validation of the Children's and Infants' Postoperative Pain Scale in Brazilian ChildrenPain Practice, 2008
- Acute Lower Respiratory Tract InfectionNew England Journal of Medicine, 2008
- Validation of an Instrument Measuring Patient Satisfaction With Chest Physiotherapy Techniques in Cystic FibrosisChest, 2000
- Analysis of behavioural and physiological parameters for the assessment of postoperative analgesic demand in newborns, infants and young children: a comprehensive report on seven consecutive studiesPediatric Anesthesia, 2000