Comparison of synchrotron radiation angiography with conventional angiography for the diagnosis of in-stent restenosis after percutaneous transluminal coronary angioplasty
Authors:
- Bernard BertrandBBBernard Bertrand
- François EstèveFEFrançois Estève
- Hélène ElleaumeHEHélène Elleaume
- Christian NemozCNChristian Nemoz
- Stefan FiedlerSFStefan Fiedler
- Alberto BravinABAlberto Bravin
- Gilles BerruyerGBGilles Berruyer
- Thierry BrochardTBThierry Brochard
- Michel RenierMRMichel Renier
- Jacques MachecourtJMJacques Machecourt
- William ThomlinsonWTWilliam Thomlinson
- Jean-François Le BasJBJean-François Le Bas
Open Access
- 25 February 2005
- journal article
- research article
- Published by Oxford University Press (OUP) in European Heart Journal
- Vol. 26 (13) , 1284-1291
Abstract
Aims Synchrotron radiation angiography (SRA) is a novel tool for minimally invasive coronary artery imaging. The method uses subtraction of two images produced at energies bracketing the iodine K-edge after intravenous infusion of iodinated contrast agent. We investigated the accuracy of SRA for detecting in-stent restenosis (ISR). Methods and results We recruited 57 men, 4–6 months after successful PTCA. We visualized the right coronary artery (RCA) in 27 patients with 36 stented segments [12 segments with ISR>50% by quantitative coronary angiography (QCA)], and the left anterior descending artery (LAD) in 30 patients with 37 stented segments (10 ISR). SRA and QCA were performed within 2 days of each other. Two experienced observers unaware of QCA data evaluated the SRA results. Image quality was good or excellent in most patients. Global sensitivity was 64%, specificity was 95%, and positive and negative predictive values were ∼85%. Inter-observer kappa concordance coefficient was 0.86. False negatives involved short eccentric lesions and superimposed segments, most frequently of the LAD. False positives occurred in intermediate stenoses slightly overestimated by SRA. Conclusion In men, this minimally invasive approach, using small radiation doses, detects significant ISR in the RCA, but the LAD poses difficulties because of superimposition with others structures.Keywords
This publication has 17 references indexed in Scilit:
- Pitfalls, Artifacts, and Remedies in Multi– Detector Row CT Coronary AngiographyRadioGraphics, 2004
- Coronary MR Angiography: Comparison of Quantitative and Qualitative Data from Four TechniquesAmerican Journal of Roentgenology, 2004
- A Polymer-Based, Paclitaxel-Eluting Stent in Patients with Coronary Artery DiseaseNew England Journal of Medicine, 2004
- Sirolimus-eluting stents for treatment of patients with long atherosclerotic lesions in small coronary arteries: double-blind, randomised controlled trial (E-SIRIUS)The Lancet, 2003
- Coronary Arteries: Contrast-enhanced MR Imaging with SH L 643A—Experience in 12 VolunteersRadiology, 2003
- Reliable Noninvasive Coronary Angiography With Fast Submillimeter Multislice Spiral Computed TomographyCirculation, 2002
- Computed Tomography and Magnetic Resonance Imaging for Noninvasive Coronary Angiography and Plaque ImagingCirculation, 2002
- Coronary Magnetic Resonance Angiography for the Detection of Coronary StenosesNew England Journal of Medicine, 2001
- Continued benefit of coronary stenting versus balloon angioplasty: One-year clinical follow-up of Benestent trialJACC, 1996
- Silent ischemia after coronary angioplasty: Evaluation of restenosis and extent of ischemia in asymptomatic patients by tomographic thallium-201 exercise imaging and comparison with symptomatic patientsJACC, 1991