Abstract
BACKGROUND: α-1-Antitrypsin (A1AT) deficiency results from a genetic disorder at 2 common loci. Diagnosis requires quantification of A1AT and subsequent identification of the specific variant. The current algorithm of laboratory testing for the diagnosis of A1AT deficiency uses a combination of quantification (nephelometry), genotyping, and/or phenotyping. We developed a multiple reaction monitoring liquid chromatography–tandem mass spectrometry (LC-MS/MS) method for simultaneous quantification of A1AT and identification of the 2 most common deficiency alleles present in 95% of the patients with A1AT deficiency. METHODS: Serum samples (n = 40) were digested with trypsin, and appropriate 13C/15N-labeled standard peptides were added. We performed LC-MS/MS analysis with a 0.5- by 150-mm C18 column and H2O:acetonitrile:n-propanol:formic acid (A:98:1:1:0.2 and B:10:80:10:0.2; flow 12 μL/min) mobile phase in positive ion mode on a TSQ Quantum triple quadrupole MS system. We measured the A1AT concentration by comparison to a calibration curve and determined the phenotype by the presence or absence of variant peptides. We compared the results to the current phenotyping assay by isoelectric focusing (IEF) and the immunonephelometry quantitative assay. RESULTS: For A1AT allele detection, in 39 of 40 samples the LC-MS/MS results were identical to those obtained by IEF gel electrophoresis. The single discrepant result was rerun by IEF at a lower dilution, and the results were in concordance. The A1AT quantification by LC-MS/MS also compared favorably with nephelometry. CONCLUSIONS: The LC-MS/MS method correlates well with current phenotyping and nephelometric assays and has the potential to improve the laboratory diagnosis of genetic A1AT deficiency.Keywords
Funding Information
- NIH (T32 GM08685)
- Arlene Kogod Center on Aging
- Noaber Foundation
- Ted Nash Foundation
- Mayo Clinic Research Committee
- David Woods Kemper Memorial Foundation
This publication has 32 references indexed in Scilit:
- Automated Determination of Serum α1-Antitrypsin by Antitryptic Activity MeasurementClinical Chemistry, 2009
- Protein Quantitation through Targeted Mass Spectrometry: The Way Out of Biomarker Purgatory?Clinical Chemistry, 2008
- Quantification of Thyroglobulin, a Low-Abundance Serum Protein, by Immunoaffinity Peptide Enrichment and Tandem Mass SpectrometryClinical Chemistry, 2008
- A New Era in Protein Quantification in Clinical Laboratories: Application of Liquid Chromatography-Tandem Mass SpectrometryClinical Chemistry, 2007
- Prediction of Missed Cleavage Sites in Tryptic Peptides Aids Protein Identification in ProteomicsJournal of Proteome Research, 2006
- A pilot study comparing the purity, functionality and isoform composition of alpha-1-proteinase inhibitor (human) productsCurrent Medical Research and Opinion, 2005
- 1-Antitrypsin deficiency * 4: Molecular pathophysiologyThorax, 2004
- 1-Antitrypsin deficiencyThorax, 2004
- Rapid and Simple Diagnosis of the Two Common α
1
-Proteinase Inhibitor Deficiency Alleles Pi*Z and Pi*S by DNA AnalysisClinical Chemistry and Laboratory Medicine (CCLM), 1996
- Molecular basis of alpha-1-antitrypsin deficiencyThe American Journal of Medicine, 1988