Automatic cerebral aneurysm detection in multimodal angiographic images
Authors:
- 1 October 2011
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 10823654,p. 3116-3120
Abstract
We propose a system to automatically detect cerebral aneurysms in 3D X-ray rotational angiography (3D-RA) images, magnetic resonance angiography (MRA) images and computed tomography angiography (CTA) images. The aneurysms are found by analyzing a blob-enhancing filtered image. Our method was tested on 65 angiographic data sets. The features leading to the best discrimination between false positives (FP) and aneurysms were identified. We achieved 96 % sensitivity with an average rate of 2.6 FP per data set in case of 3D-RA, 94 % sensitivity with an average rate of 8.0 FP per data set in case of MRA and 90 % sensitivity with an average rate of 28.1 FP per data set with CTA, respectively.Keywords
This publication has 7 references indexed in Scilit:
- Automated detection of intracranial aneurysms based on parent vessel 3D analysisMedical Image Analysis, 2010
- Computer-Aided Detection of Intracranial Aneurysms in MR AngiographyJournal of Digital Imaging, 2009
- Subarachnoid haemorrhageThe Lancet, 2007
- Aneurysmal Subarachnoid HemorrhageNew England Journal of Medicine, 2006
- Computerized detection of intracranial aneurysms for three‐dimensional MR angiography: Feature extraction of small protrusions based on a shape‐based difference image techniqueMedical Physics, 2006
- Computer-Aided Diagnosis of Intracranial Aneurysms in MRA Images with Case-Based ReasoningIEICE Transactions on Information and Systems, 2006
- The detection and management of unruptured intracranial aneurysmsBrain, 2000