Biological Variation Estimates Obtained from 91 Healthy Study Participants for 9 Enzymes in Serum
Open Access
- 1 June 2017
- journal article
- Published by Oxford University Press (OUP) in Clinical Chemistry
- Vol. 63 (6) , 1141-1150
Abstract
BACKGROUND: We sought to develop estimates of biological variation (BV) for 9 enzymes in blood serum as part of the European Biological Variation Study. METHODS: Ninety-one healthy study participants (38 male and 53 female, 21–69 years old) were phlebotomized in each of 10 consecutive weeks at 6 European laboratories. The same preanalytical sample-handling protocol was followed at each center before transport to San Raffaele Hospital, Milan, Italy, for analysis. Sera were stored at −80 °C before analysis in duplicate within a single run on an ADVIA 2400 Clinical Chemistry System (Siemens Healthcare) following a protocol designed to minimize analytical imprecision. Assay traceability was established using frozen sera with target values assigned by reference methods. The results were subjected to outlier analysis before CV-ANOVA to deliver valid BV estimates. Results for 9 enzymes were subsequently partitioned for graphical display allowing visual assessment of the effects of country of origin, sex, and age on BV estimates. RESULTS: We found no effect of country upon the observed variation, but overall sex-related differences were evident for alanine amino transferase (ALT), γ-glutamyl transferase (GGT), and creatine kinase (CK). The following estimates for within-subject BV (CVI) and between-subject BV (CVG), respectively, were obtained: ALT: 9.3%, 28.2%; aspartate aminotransferase: 9.5%, 20.3%; GGT: 8.9%, 41.7%; alkaline phosphatase : 5.3%, 24.9%; lactate dehydrogenase: 5.2%, 12.6%; CK: 14.5%, 31.5%; amylase: 6.8%, 30.4%; pancreatic α-amylase: 6.3%, 24.9%; and lipase (LIP): 7.7%, 23.8%. CONCLUSIONS: All CVI and some CVG estimates were lower than those reported in the online BV 2014 updated database. Analytical performance specifications derived from BV can be applied internationally.Keywords
Funding Information
- Siemens Healthcare
This publication has 19 references indexed in Scilit:
- A systematic review of data on biological variation for alanine aminotransferase, aspartate aminotransferase and γ-glutamyl transferaseClinical Chemistry and Laboratory Medicine (CCLM), 2013
- Serum Enzymes2012
- Gross Overestimation of Total Allowable Error Based on Biological VariationClinical Chemistry, 2011
- IFCC Primary Reference Procedures for the Measurement of Catalytic Activity Concentrations of Enzymes at 37°C. Part 1. The Concept of Reference Procedures for the Measurement of Catalytic Activity Concentrations of EnzymesClinical Chemistry and Laboratory Medicine (CCLM), 2002
- Biological variation in the catalytic concentration of pancreatic a-amylase and triacylglycerol lipase in serumScandinavian Journal of Clinical and Laboratory Investigation, 1991
- Total Amylase and Pancreatic Isoamylase in Serum and Urine: Considerations from Data on Biological VariationAnnals of Clinical Biochemistry: International Journal of Laboratory Medicine, 1989
- Generation and Application of Data on Biological Variation in Clinical ChemistryCritical Reviews in Clinical Laboratory Sciences, 1989
- An analysis of variance test for normality (complete samples)Biometrika, 1965
- Processing Data for OutliersBiometrics, 1953
- THE DISTRIBUTION OF THE LARGEST OF A SET OF ESTIMATED VARIANCES AS A FRACTION OF THEIR TOTALAnnals of Eugenics, 1941