Abstract
Accurate time synchronization is essential for data fusion, deterministic scheduling, and other fundamental operations in industrial wireless sensor networks. The relative clock skew plays a key role in popular distributed time synchronization and directly affects the estimation accuracy of clock compensations. However, communication delays are inevitable and unpredictable in practical scenarios, which makes an error calculation of relative clock skew for most synchronization protocols. This paper investigates the time synchronization problem with Gaussian distribution delays. A maximum likelihood estimator (MLE) of the relative clock skew is derived, and its Cramer-Rao lower bound is given. Without modifying the synchronization protocol and packet format, MLE gathers the observed values in past several synchronization periods to accurately estimate the relative clock skew of current round. The proposed MLE is independent of clock skew and clock offset estimations. It can be applied to different distributed protocols. Extensive simulation results indicate that the convergence accuracy of the proposed MLE-based synchronization protocols is better than that with the ATS, GTSP, and MTS protocols. In addition, the accuracy of the estimator depends on the synchronization period and the window length of MLE, which provides flexible accuracy levels for various industrial applications.
Funding Information
  • National Natural Science Foundation of China (62002140)
  • Natural Science Foundation of Jiangsu Province (BK20200887)
  • Doctor’s Program of Entrepreneurship and Innovation in Jiangsu Province

This publication has 32 references indexed in Scilit: