System Design for Non-Destructive near Infrared Analyses of Chemical Components and Total Aerobic Bacteria Count of Raw Milk
- 1 January 2008
- journal article
- Published by SAGE Publications in Journal of Near Infrared Spectroscopy
- Vol. 16 (4) , 389-398
Abstract
In order to develop a system for quality and safety evaluation of non-homogenised raw milk using near infrared (NIR) spectroscopy, two stages of research have been conducted. The first stage was the development of a compact NIR system for measuring the major constituents such as fat and protein in an aseptic environment. The second stage was the measurement of the total aerobic bacteria count (TBC). In the first stage, two compact sample holders for commercially-available capped test tube were designed. One system was equipped with an NIRSystem6500 research-type NIR spectrophotometer, hereafter referred to as MilkSpec-2. The other was equipped with a hand-held NIR spectrophotometer, the FT20, hereafter referred to as MilkSpec-3. For MilkSpec-2, the highly satisfactory results were obtained with the multiple determination coefficients of determination ( R2) = 0.99 and 0.96, and standard errors of prediction (SEP) = 0.03% and 0.07% for fat and protein, respectively. The results for MilkSpec-3 were also satisfactory but inferior compared with MilkSpec-2; the results were R2 = 0.99 and 0.91 and SEP=0.06% and 0.08% for fat and protein, respectively. In the following stage, MilkSpec-2 was used for the measurement of TBC in terms of log colony forming units (CFU) mL−1. In the case of TBC measurements, where the concentration of bacteria itself or its by-products were very low, three kinds of commercial test tube made of the same kind of glass but differing in diameter were used to identify the appropriate physical pathlength. It was found that the medium sized test tube with an external diameter of 20 mm provided the best calibration results with R2 = 0.83, SEP = 0.55 log (CFU) mL−1 and the ratio of standard deviation of reference data in the validation set to SEP (RPD) = 2.33. The analysis of the calibration structure indicated that the information related to absorptions by bacteria metabolites such as lactic acid, urea and those of the carbon sources such as lactose and protein in milk might play substantial roles in the NIR-TBC determination.Keywords
This publication has 19 references indexed in Scilit:
- Near Infrared Spectra of Cows' Milk for Milk Quality Evaluation: Disease Diagnosis and Pathogen IdentificationJournal of Near Infrared Spectroscopy, 2006
- Detection and Identification of Bacteria in a Juice Matrix with Fourier Transform–Near Infrared Spectroscopy and Multivariate AnalysisJournal of Food Protection, 2004
- Rapid Detection and Identification of Bacterial Strains By Fourier Transform Near-Infrared SpectroscopyJournal of Agricultural and Food Chemistry, 2001
- Somatic cell count determination in cow's milk by near-infrared spectroscopy: a new diagnostic tool.Journal of Animal Science, 2001
- Near-infrared spectroscopy for biomonitoring: influence of somatic cell count on cow's milk composition analysisInternational Dairy Journal, 2001
- Short-Wave Near-Infrared Spectroscopy of Biological Fluids. 1. Quantitative Analysis of Fat, Protein, and Lactose in Raw Milk by Partial Least-Squares Regression and Band AssignmentAnalytical Chemistry, 2000
- Near-Infrared Spectroscopy for Dairy Management: Measurement of Unhomogenized Milk CompositionJournal of Dairy Science, 1999
- Review of Process and Non-invasive Near-Infrared and Infrared Spectroscopy: 1993–1999Applied Spectroscopy Reviews, 1999
- Bacterial Monitoring in Vials Using a Spectrophotometric Assimilation MethodPharmaceutical Research, 1992
- Screening of tomato purée for excessive mould content by near infrared spectroscopy: A preliminary evaluationJournal of the Science of Food and Agriculture, 1987