Discriminating time-varying loads and rotor cage fault in induction motors
Authors:
- 1 August 2013
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 309-316
Abstract
Diagnosis of electrical machines are becoming more and more important issues in the field of electrical machines as new data processing technique. Motor Current Stator Analysis (MCSA) are usually used to detect the broken bars. In several industrial applications, the motor is subjected to load torque variations of low frequencies, which have effects similar to rotor faults in the current spectrum and result of diagnostic procedure may be ambigues. Discriminating rotor cage fault from oscillating load effects in Induction motors must be considered. In this paper, we present a study based on the application of the active and reactive power signature analyses for discriminating broken rotor bars from mechanical load oscillation effects in operating three-phase squirrel cage induction motors. This method is attractive because it does not need to interrupt the operating system. Finite element method was used to perform dynamical simulation, which leads to more precise results than other models, as the reel geometry and winding layout of the machine are used. The computer simulations and laboratory experiments results show the interest and the efficiency of this technique for the correct distinction between broken rotor bars and load oscillations.Keywords
This publication has 12 references indexed in Scilit:
- An Active–Reactive Power Method for the Diagnosis of Rotor Faults in Three-Phase Induction Motors Operating Under Time-Varying Load ConditionsIEEE Transactions on Energy Conversion, 2012
- Analysis of induction motor with broken rotor bars using finite element method2011
- Discriminating the Simultaneous Occurrence of Three-Phase Induction Motor Rotor Faults and Mechanical Load Oscillations by the Instantaneous Active and Reactive Power Media Signature AnalysesIEEE Transactions on Industrial Electronics, 2011
- Discriminating broken rotor bar from oscillating load effects using the instantaneous active and reactive powersIET Electric Power Applications, 2010
- Separating Broken Rotor Bars and Load Oscillations on IM Fault Diagnosis Through the Instantaneous Active and Reactive CurrentsIEEE Transactions on Industrial Electronics, 2009
- Rotor cage fault diagnosis in three-phase induction motors by the total instantaneous power spectral analysis2003
- Quantitative evaluation of induction motor broken bars by means of electrical signature analysisIEEE Transactions on Industry Applications, 2001
- Transient finite element analysis for an induction motor with external circuit connections and electromechanical couplingIEEE Transactions on Energy Conversion, 1999
- Effects of time-varying loads on rotor fault detection in induction machinesIEEE Transactions on Industry Applications, 1995
- Methods of Motor Current Signature AnalysisElectric Machines & Power Systems, 1992