Measurement of interfacial temperatures during testing of a subscale aircraft brake
- 14 March 2001
- journal article
- Published by IOP Publishing in Journal of Physics D: Applied Physics
- Vol. 34 (6) , 976-984
Abstract
Interfacial temperatures have been measured using fibre optic inserts in the stationary brake ring during ring-on-ring, subscale dynamometer aircraft brake testing. The brake materials are carbon fibre-reinforced, carbon-matrix (carbon-carbon) composites. The temperature distribution varies with dynamometer test conditions and demonstrates the non-uniformity of contact pressure within the interface. A two-dimensional, axis-symmetric finite element model (FEM) is presented that is used to estimate temperature profiles during braking using either a constant pressure or constant energy flux assumption. The model incorporates the measured temperature-dependence of the thermal diffusivity and specific heat capacity for the composite materials. The surface temperatures obtained from the FEM are compared with the measured surface temperatures. Substantial differences between the two results are observed and discussed.Keywords
This publication has 3 references indexed in Scilit:
- Transient Thermoelastic Analysis of Composite Brake DisksJournal of Reinforced Plastics and Composites, 1995
- Thermal transport properties of carbon–carbon fibre composites II. Microstructural characterizationProceedings of the Royal Society of London. Series A: Mathematical and Physical Sciences, 1990
- Design and engineering of carbon brakesPhilosophical Transactions of the Royal Society of London. Series A, Mathematical and Physical Sciences, 1980