Reliability of non-invasive cardiac output measurement in individuals with tetraplegia
Authors:
- S HostettlerSHS Hostettler
- J BrechbühlJBJ Brechbühl
- C M SpenglerCSC M Spengler
- 21 December 2010
- journal article
- research article
- Published by Springer Nature in Spinal Cord
- Vol. 49 (5) , 665-671
Abstract
The study is conducted on the basis of comparative-repeated measures. The objective of this study is to assess the reliability of non-invasive cardiac output (CO) measurements in individuals with tetraplegia (TP) at rest and during exercise using Innocor, and to test the hypothesis that CO measurements are less reliable in TP than in able-bodied (AB) individuals. Ambulatory volunteers, Switzerland. Nine male motor-complete TP (C5-C7) and nine pair-matched AB performed repeated CO measurements at rest and during submaximal arm-crank and wheelchair exercises in four different test sessions. Within- and between-day reliabilities were compared between TP and AB. Mean differences between measurements at rest (TP vs AB, within-day: 0.1±0.5 vs 0.2±0.6 l min(-1), between-day: -0.7±0.6 vs -0.1±0.8 l min(-1)), during arm-crank (TP vs AB, within-day: 0.1±0.9 vs 0.5±0.7 l min(-1), between-day: -0.3±1.1 vs 0.0±1.1 l min(-1)) and wheelchair exercises (TP vs AB, within-day: 0.3±1.2 vs -0.1±0.8 l min(-1), between-day: 0.1±1.1 vs 0.5±0.9 l min(-1)) were not significantly different between TP and AB (all P>0.05). Coefficients of variation in TP (within-day, rest: 6.8%, arm-crank: 9.6% and wheelchair: 10.8%; between-day, rest: 11.9%, arm-crank: 11.2% and wheelchair: 10.3%) and in AB (within-day, rest: 7.7%, arm crank: 6.8% and wheelchair: 6.0%; between-day, rest: 9.2%, arm crank: 8.5% and wheelchair: 8.0%) indicated acceptable reliability. In contrast to our hypothesis, we found non-invasive CO measurements using Innocor to be as reliable in TP as they are in AB. Consequently, Innocor can be recommended for repeated assessments of CO in TP within routine diagnostics or for evaluation of training progress.Keywords
This publication has 21 references indexed in Scilit:
- Autonomic function following cervical spinal cord injuryRespiratory Physiology & Neurobiology, 2009
- Reliability of Measurements with InnocorTMduring ExerciseInternational Journal of Sports Medicine, 2009
- Cardiovascular Disease in Spinal Cord InjuryAmerican Journal of Physical Medicine & Rehabilitation, 2007
- Noninvasive Measurement of Cardiac Output During Exercise by Inert Gas Rebreathing Technique: A New Tool for Heart Failure EvaluationJACC, 2005
- Standardisation of spirometryEuropean Respiratory Journal, 2005
- A prospective assessment of mortality in chronic spinal cord injurySpinal Cord, 2005
- Non-invasive measurement of cardiac output in heart failure patients using a new foreign gas rebreathing techniqueClinical Science, 2002
- Reliability and Validity of Measures of Cardiac Output During Incremental to Maximal Aerobic ExerciseSports Medicine, 1999
- Statistical Methods For Assessing Measurement Error (Reliability) in Variables Relevant to Sports MedicineSports Medicine, 1998