Bubble-CPAP vs. Ventilatory-CPAP in Preterm Infants with Respiratory Distress
Open Access
- 1 June 2011
- journal article
- research article
- Vol. 21 (2) , 151-158
Abstract
Objective: Application of Continuous Positive Airway Pressure (CPAP) in neonate with respiratory distress is associated with reduction of respiratory failure, reduced complications and mortality. Bubble CPAP (B-CPAP) and ventilator-derived CPAP (V-CPAP) are two most popular CPAP modes. We aimed to determine whether B-CPAP and V-CPAP would have different survival rate and possible complications. Methods: This prospective clinical trial was performed on SO preterm neonates weighing 1000-2000 gr who were admitted to the neonatal intensive care unit of Afzalipoor Hospital because of respiratory distress between June 2009 and May 2010. Patients were randomly allocated into treatment groups using minimization technique. Survival analysis was applied to estimate and compare survival rates. Duration of oxygen therapy, hospital stay as well as hospitalization costs were compared using independent sample t-test. Findings: Estimated survival rates at 24 hours in B-CPAP and V-CPAP groups were 100% and 77% respectively. Corresponding figures at 48 hours were 100% and 71%. In addition the hospitalization cost in V-CPAP group was significantly higher than in B-CPAP group. Conclusion: According to our results, B-CPAP was effective in the treatment of neonates who were suffering from respiratory distress and reduced the duration of hospital stay. In addition to mentioned benefits, its low cost may be the reason to use B-CPAP broadly compared with V-CPAP.Keywords
This publication has 40 references indexed in Scilit:
- A Pilot Study of Comparison of BCPAP vs. VCPAP in Preterm Infants with Early Onset Respiratory DistressJournal of Tropical Pediatrics, 2009
- Bubble Continuous Positive Airway Pressure, A Potentially Better Practice, Reduces the Use of Mechanical Ventilation Among Very Low Birth Weight Infants With Respiratory Distress SyndromePediatrics, 2009
- Bubble Continuous Positive Airway Pressure Enhances Lung Volume and Gas Exchange in Preterm LambsAmerican Journal of Respiratory and Critical Care Medicine, 2007
- An Evaluation of Bubble-CPAP in a Neonatal Unit in a Developing Country: Effective Respiratory Support That Can Be Applied By NursesJournal of Tropical Pediatrics, 2005
- Variables Associated with the Early Failure of Nasal CPAP in Very Low Birth Weight InfantsThe Journal of Pediatrics, 2005
- Quality Assessment of Perinatal Regionalization by Multivariate AnalysisObstetrics & Gynecology, 1997
- Predictors of early childhood outcome in candidates for extracorporeal membrane oxygenationThe Journal of Pediatrics, 1996
- Severe respiratory failure in neonates: Mortality and morbidity rates and neurodevelopmental outcomesThe Journal of Pediatrics, 1994
- Changing incidence of bronchopulmonary dysplasiaThe Journal of Pediatrics, 1979
- A new device for CPAP by nasal routeCritical Care Medicine, 1975