Applying mean systemic filling pressure to assess the response to fluid boluses in cardiac post-surgical patients
Authors:
- 8 January 2015
- journal article
- Published by Springer Nature in Intensive Care Medicine
- Vol. 41 (2) , 265-272
Abstract
To evaluate an analogue of mean systemic filling pressure (P msa) and derived variables to quantitatively assess the effectiveness of volume expansion in increasing cardiac output. Sixty-one cardiac post-surgical patients were studied and 107 fluid boluses were captured. Cardiac output, mean arterial pressure and right atrial pressure were recorded with P msa before and after a bolus fluid. An increase in cardiac output greater than 10 % following a fluid bolus defined a patient as a responder. Cardiac power (i.e. the product of arterial pressure and cardiac output) and P msa to right atrial pressure gradient (i.e. the driving pressure for venous return and hence cardiac output) were evaluated to assess the efficiency of volume expansion to increase cardiac output. Cardiac power relative to P msa (CPvol), its dynamic changes and the dynamic changes in P msa–right atrial pressure gradient relative to the P msa change (E vol) were investigated. CPvol was lower and E vol was higher in responders vs. non-responders. Furthermore, in patients receiving a second fluid bolus, E vol correlated with the degree of increase in cardiac output. Multivariate regression analysis identified both CPvol and E vol as independent variables associated with volume responsiveness. Using an algorithm to derive a mean systemic filling pressure analogue, cardiac power and dynamic measures of the venous return pressure gradient relative to the mean systemic filling pressure provided an assessment of the efficiency of volume expansion in post-surgical cardiac patients.Keywords
This publication has 23 references indexed in Scilit:
- Cardiac Power Index, Mean Arterial Pressure, and Simplified Acute Physiology Score II Are Strong Predictors of Survival and Response to Revascularization in Cardiogenic ShockShock, 2014
- Functional haemodynamic monitoringCurrent Opinion in Critical Care, 2014
- Evaluation of pulse pressure variation validity criteria in critically ill patients: a prospective observational multicentre point-prevalence study †British Journal of Anaesthesia, 2013
- Surviving Sepsis Campaign: International Guidelines for Management of Severe Sepsis and Septic Shock, 2012Intensive Care Medicine, 2013
- Therapeutic control of the circulationJournal of Clinical Monitoring and Computing, 2008
- Thermodilution cardiac output – are three injections enough?Acta Anaesthesiologica Scandinavica, 2004
- Static filling pressure in patients during induced ventricular fibrillationAmerican Journal of Physiology-Heart and Circulatory Physiology, 2003
- Use of a mean systemic filling pressure analogue during the closed-loop control of fluid replacement in continuous hemodiafiltrationJournal of Critical Care, 1994
- Regulation of Cardiac OutputAnesthesiology, 1968
- Effect of Blood Transfusion and Hemorrhage on Cardiac Output and on the Venous Return CurveAmerican Journal of Physiology-Legacy Content, 1958