Abstract
Colour measurement was investigated as a means to evaluate equivalent firing temperatures of ancient pottery. Colour coordinates were determined on samples of six clays previously fired, and then refired, in the temperature range 600–1100°C. Under the adopted conditions, significant variations of colour hue and saturation were normally observed on refired samples only after the original firing temperature had been exceeded; less reliable information was provided by luminosity. Original firing temperatures of clay samples were correctly recognized in most cases by projecting the points representing samples’ colour on to the a*b* plane of the ClEL*a*b* colour space.