Metal-On-Metal Hip Replacements: Wear Performance and Cellular Response To Wear Particles
Authors:
- 1 January 1999
- book chapter
- Published by ASTM International
- p. 193-209
Abstract
This study examined the clinical wear performance of second-generation metal-on-metal (M-M) total hips and evaluated the cellular reaction to, and characteristics of, the wear particles. Twenty cobalt chrome (CoCr) M-M THRs were studied, including ten Metasul conventional total hips (THRs), and ten McMinn surface replacements (SRs). As in the first-generation M-M hips, wear ranged from undetectable to 32 μm in the SR femoral shells (ave 15.7 ± 14 μm) and from undetectable to 19 μm in the THR balls (ave 10.1 ± 7 μm). Self-polishing of third body scratches was evident. Two THRs exhibited clusters of micropits, which had been described on first-generation M-M hips but these did not appear to correlate with accelerated wear. CoCr particles were either dense or amorphous and were mostly in the nanometer size range. There were generally fewer macrophages in the tissues than seen with M-PE THRs, and there was a more inflammatory response to bone cement particles compared with metal particles. Nevertheless, the long-term response to these very small CoCr particles should be monitored.Keywords
This publication has 21 references indexed in Scilit:
- Wear and osteolysis in total joint replacementsActa Orthopaedica, 1998
- Human monocyte/macrophage response to cobalt‐chromium corrosion products and titanium particles in patients with total joint replacementsJournal of Orthopaedic Research, 1997
- In Vivo Wear of 3 Types of Metal on Metal Hip Prostheses During 2 Decades of UseClinical Orthopaedics and Related Research, 1996
- Metal Versus Polyethylene Wear Particles in Total Hip ReplacementsClinical Orthopaedics and Related Research, 1996
- Tissue Reaction to Metal on Metal Total Hip ProsthesesClinical Orthopaedics and Related Research, 1996
- Wear Behavior and Histopathology of Classic Cemented Metal on Metal Hip EndoprosthesesClinical Orthopaedics and Related Research, 1996
- Distribution of Cobalt Chromium Wear and Corrosion Products and Biologic ReactionsClinical Orthopaedics and Related Research, 1996
- INTERLEUKIN-1 PRODUCTION BY ACTIVATED MACROPHAGES SURROUNDING LOOSENED ORTHOPAEDIC IMPLANTS: A POTENTIAL ROLE IN OSTEOLYSISRheumatology, 1994
- Mechanism and Clinical Significance of Wear Debris-Induced OsteolysisClinical Orthopaedics and Related Research, 1992
- Cementless Total Joint Arthroplasty Prostheses With Titanium-Alloy Articular SurfacesClinical Orthopaedics and Related Research, 1990