Using CONTAM to design ventilation strategy of negative pressure isolation ward considering different height of door gaps
Authors:
- Mingyao MaMMMingyao Ma
- Changsheng CaoCCChangsheng Cao
- Yukun XuYXYukun Xu
- Zhijian LiuZhijian Liu
- Lingjie ZengLZLingjie Zeng
- Chengquan ZhangCZChengquan Zhang
- Jun GaoJGJun Gao
Open Access
- 1 February 2024
- journal article
- research article
- Published by KEAI Publishing in Energy and Built Environment
- Vol. 5 (1) , 32-45
Abstract
Infectious disease departments in hospitals require pressure gradient to create unidirectional airflow to prevent the spread of contaminants, typically by creating active air infiltration through the difference between supply and exhaust air volumes. The door gap is the channel of air flow between rooms, so its height has an important influence on the pressure difference and infiltration air volume of the room. There is still a lack of research on setting reasonable ventilation strategies according to the different heights of door gaps at different positions in the building. In this study, model of a set of isolation wards was established and analyzed using the multi-zone simulation software CONTAM, and the ventilation strategies with different heights of door gaps were applied to the actual infection diseases department. The results show that in a building with ventilation system divided by functional area, the difference in the height of the door gaps requires different active infiltration air volumes. Pressure fluctuations in the medical and patient corridors are greater than in other rooms. The significance of this study is to understand the active infiltration of air to guide the design and operation of ventilation systems in infectious disease hospitals or building remodeled to isolate close contacts of COVID-19 patients. It is also instructive for the design of pressure gradients in clean workshops, biological laboratories, and other similar buildings.Keywords
This publication has 27 references indexed in Scilit:
- Validation and assessment of the CFD-0 module of CONTAM software for airborne contaminant transport simulation in laboratory and hospital applicationsBuilding and Environment, 2018
- A Comparative Study of Indoor Radon Levels between Two Similar Dwellings Using CONTAM Software
Environments, 2018
- CFD study on gaseous pollutant transmission characteristics under different ventilation strategies in a typical chemical laboratoryBuilding and Environment, 2017
- Study on present situation and optimization strategy of infiltration air in a train station in winterProcedia Engineering, 2017
- Using coupled energy, airflow and indoor air quality software (TRNSYS/CONTAM) to evaluate building ventilation strategiesBuilding Services Engineering Research & Technology, 2015
- Simulation of Air Infiltration of Australian Housing and its Impact on Energy ConsumptionEnergy Procedia, 2015
- Simulation of pollution transport in buildings: the importance of taking into account dynamic thermal effectsBuilding Services Engineering Research & Technology, 2014
- Using CFD Capabilities of CONTAM 3.0 for Simulating Airflow and Contaminant Transport in and around BuildingsHVAC&R Research, 2010
- The influence of gaps of fire-resisting doors on the smoke spread in a building fireFire Safety Journal, 2006
- Laboratory Chemical Hoods: A Historical PerspectiveAIHA Journal, 2003