Design and Calibration of a Large Open-Ended Coaxial Probe for the Measurement of the Dielectric Properties of Concrete
Authors:
- 12 September 2008
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Microwave Theory and Techniques
- Vol. 56 (10) , 2322-2328
Abstract
The subject of this paper is the design and calibration of an open-ended coaxial probe for the nondestructive measurement of the dielectric properties of concrete. Measurements are made between 100-900 MHz, frequencies which are often used in geophysics and civil engineering for ground penetrating radar inspection. The probe is calibrated using measurements on saline solutions in conjunction with three different mathematical techniques for comparative study. Measurements of mortar and concrete specimens having different water/cement ratios were made in order to observe the standard deviations due to their heterogeneous nature. Similar to the case of relatively homogeneous rock specimens (limestone and granite), the standard deviation for heterogeneous concrete samples do not exceed 5%. In addition, the effect of the concrete's porosity on its dielectric properties was clearly observed: measured permittivity between 4-4.5 at 900 MHz for porous concrete, and between 6.5-7.5 at 900 MHz for dense concrete.Keywords
This publication has 15 references indexed in Scilit:
- The co-axial aperture electromagnetic sensor and its application in material characterizationMeasurement Science and Technology, 1997
- An improved technique for permittivity measurements using a coaxial probeIEEE Transactions on Instrumentation and Measurement, 1997
- A comparative study of four open-ended coaxial probe models for permittivity measurements of lossy dielectric/biological materials at microwave frequenciesIEEE Transactions on Microwave Theory and Techniques, 1996
- On the measurement of the complex permittivity of materials by an open-ended coaxial probeIEEE Microwave and Guided Wave Letters, 1995
- Permittivity measurements using open-ended sensors and reference liquid calibration-an uncertainty analysisIEEE Transactions on Microwave Theory and Techniques, 1992
- Improved calibration of a large open-ended coaxial probe for dielectric measurementsIEEE Transactions on Instrumentation and Measurement, 1991
- ANA Calibration Method for Measurements of Dielectric PropertiesIEEE Transactions on Instrumentation and Measurement, 1983
- Measurement of Radio Frequency Permittivity of Biological Tissues with an Open-Ended Coaxial Line: Part IIEEE Transactions on Microwave Theory and Techniques, 1982
- Measurement of Radio Frequency Permittivity of Biological Tissues with an Open-Ended Coaxial Line: Part II - Experimental ResultsIEEE Transactions on Microwave Theory and Techniques, 1982
- An improved model for the dielectric constant of sea water at microwave frequenciesIEEE Transactions on Antennas and Propagation, 1977