Hyperangulated vs. Macintosh videolaryngoscopy in adults with anticipated difficult airway management: a randomised controlled trial
Top Cited Papers
Open Access
- 24 May 2024
- journal article
- research article
- Published by Wiley in Anaesthesia
- Vol. 79 (9) , 957-966
Abstract
Summary: Background: It is not certain whether the blade geometry of videolaryngoscopes, either a hyperangulated or Macintosh shape, affects glottic view, success rate and/or tracheal intubation time in patients with expected difficult airways. We hypothesised that using a hyperangulated videolaryngoscope blade would visualise a higher percentage of glottic opening compared with a Macintosh videolaryngoscope blade in patients with expected difficult airways. Methods: We conducted an open‐label, patient‐blinded, randomised controlled trial in adult patients scheduled to undergo elective ear, nose and throat or oral and maxillofacial surgery, who were anticipated to have a difficult airway. All airway operators were consultant anaesthetists. Patients were allocated randomly to tracheal intubation with either hyperangulated (C‐MAC D‐BLADE™) or Macintosh videolaryngoscope blades (C‐MAC™). The primary outcome was the percentage of glottic opening. First attempt success was designated a key secondary outcome. Results: We assessed 2540 adults scheduled for elective head and neck surgery for eligibility and included 182 patients with expected difficult airways undergoing orotracheal intubation. The percentage of glottic opening visualised, expressed as median (IQR [range]), was 89 (69–99 [0–100])% with hyperangulated videolaryngoscope blades and 54 (9–90 [0–100])% with Macintosh videolaryngoscope blades (p < 0.001). First‐line hyperangulated videolaryngoscopy failed in one patient and Macintosh videolaryngoscopy in 12 patients (13%, p = 0.002). First attempt success rate was 97% with hyperangulated videolaryngoscope blades and 67% with Macintosh videolaryngoscope blades (p < 0.001). Conclusions: Glottic view and first attempt success rate were superior with hyperangulated videolaryngoscope blades compared with Macintosh videolaryngoscope blades when used by experienced anaesthetists in patients with difficult airways.Keywords
This publication has 23 references indexed in Scilit:
- Videolaryngoscopy as a first-intention technique for tracheal intubation in unselected surgical patients: a before and after observational studyBritish Journal of Anaesthesia, 2022
- Videolaryngoscopy versus direct laryngoscopy for adults undergoing tracheal intubationCochrane Database of Systematic Reviews, 2022
- 2022 American Society of Anesthesiologists Practice Guidelines for Management of the Difficult Airway *Anesthesiology, 2021
- Comparing Emergency Department First-Attempt Intubation Success With Standard-Geometry and Hyperangulated Video LaryngoscopesAnnals of Emergency Medicine, 2020
- Improving laryngoscopy technique and success with the C-MAC® D blade: development and dissemination of the ‘Bath C-MAC D blade guide’British Journal of Anaesthesia, 2020
- Universal videolaryngoscopy: the importance of choosing the right device. Reply to ‘Cognitive re-engineering after a 15-year experience with routine videolaryngoscopy' (Br J Anaesth 2019; 122: e57–8)British Journal of Anaesthesia, 2019
- Will This Patient Be Difficult to Intubate?JAMA, 2019
- A randomised clinical trial comparing the ‘sniffing’ and neutral position using channelled (KingVision ® ) and non‐channelled (C‐ MAC ® ) videolaryngoscopesAnaesthesia, 2018
- Universal videolaryngoscopy: a structured approach to conversion to videolaryngoscopy for all intubations in an anaesthetic and intensive care departmentBritish Journal of Anaesthesia, 2018
- Major complications of airway management in the UK: results of the Fourth National Audit Project of the Royal College of Anaesthetists and the Difficult Airway Society. Part 1: AnaesthesiaBritish Journal of Anaesthesia, 2011