Evanescent Field Absorption-Based Fiber Optic Sensor for Detecting Power Transformer Oil Degradation
- 2 November 2021
- journal article
- research article
- Published by Taylor & Francis in Fiber and Integrated Optics
- Vol. 40 (4-6) , 229-248
Abstract
Observing the transformer oil quality is essential for the transformer’s health and system. The aging state of the transformer oils and the average remaining life accordingly can be determined using the breakdown voltage (BDV) test, ultraviolet-visible (UV-Vis) spectroscopy, and the refractive index (RI) standard methods. The subject of this study is to design and manufacture a much simpler and low-cost, evanescent field absorption-based fiber optic sensor (EFA-FOS) compatible with these proven standard methods and to perform a comparative performance analysis by determining a critical voltage threshold. Apart from the expensive and cumbersome standard methods mentioned above, the usability of the oil is carried out, thanks to the online sensor system, with the pretest using this critical voltage value. EFA-FOS measurement results of oil samples can determine the samples’ aging degree with high accuracy. The samples’ RI is determined with EFA-FOS with a sensitivity of −70 V/RIU and a linearity of 0.98 (R2). A strong relationship has also been determined between the sensor output and measured BDV with a regression constant of 0.86 (R2). Graphical AbstractKeywords
This publication has 49 references indexed in Scilit:
- Determination of phenol, m-cresol and o-cresol in transformer oil by HPLC methodElectric Power Systems Research, 2012
- A Review of Transformer LossesElectric Power Components and Systems, 2009
- Determination of the optimal wavelength for temperature independent detection of commercial gasoline with a polymer cladding optical fiberOptics Communications, 2007
- Fiber-Optic Chemical Sensors and BiosensorsAnalytical Chemistry, 2006
- An evanescent-wave optical fiber relative humidity sensor with enhanced sensitivitySensors and Actuators B: Chemical, 2005
- Regression through the OriginTeaching Statistics, 2003
- Refractive Index Measurement and its ApplicationsPhysica Scripta, 2002
- Evanescent wave absorption based fiber optic pH sensor prepared by dye doped sol-gel immobilization techniqueOptics Communications, 1997
- An expert system for transformer fault diagnosis using dissolved gas analysisIEEE Transactions on Power Delivery, 1993
- Long path fiber-optic sensor for evanescent field absorbance measurementsAnalytical Chemistry, 1988