Novel metallic implantation technique for osteochondral defects of the medial talar dome
Authors:
- Christiaan Ja van BergenCBChristiaan Ja van Bergen
- Maartje ZengerinkMZMaartje Zengerink
- Leendert BlankevoortLBLeendert Blankevoort
- Maayke N van SterkenburgMSMaayke N van Sterkenburg
- Jakob van OldenrijkJOJakob van Oldenrijk
- C Niek van DijkCDC Niek van Dijk
Open Access
- 2 June 2010
- journal article
- Published by Medical Journals Sweden AB in Acta Orthopaedica
- Vol. 81 (4) , 495-502
Abstract
A metallic inlay implant (HemiCAP) with 15 offset sizes has been developed for the treatment of localized osteochondral defects of the medial talar dome. The aim of this study was to test the following hypotheses: (1) a matching offset size is available for each talus, (2) the prosthetic device can be reproducibly implanted slightly recessed in relation to the talar cartilage level, and (3) with this implantation level, excessive contact pressures on the opposite tibial cartilage are avoided. The prosthetic device was implanted in 11 intact fresh-frozen human cadaver ankles, aiming its surface 0.5 mm below cartilage level. The implantation level was measured at 4 margins of each implant. Intraarticular contact pressures were measured before and after implantation, with compressive forces of 1,000-2,000 N and the ankle joint in plantigrade position, 10 dorsiflexion, and 14 plantar flexion. There was a matching offset size available for each specimen. The mean implantation level was 0.45 (SD 0.18) mm below the cartilage surface. The defect area accounted for a median of 3% (0.02-18) of the total ankle contact pressure before implantation. This was reduced to 0.1% (0.02-13) after prosthetic implantation. These results suggest that the implant can be applied clinically in a safe way, with appropriate offset sizes for various talar domes and without excessive pressure on the opposite cartilage.Keywords
This publication has 43 references indexed in Scilit:
- Treatment of osteochondral lesions of the talus: a systematic reviewKnee Surgery, Sports Traumatology, Arthroscopy, 2009
- In vivo cartilage contact deformation of human ankle joints under full body weightJournal of Orthopaedic Research, 2008
- Resurfacing of the First Metatarsal Head in the Treatment of Hallux RigidusTechniques in Foot & Ankle Surgery, 2008
- Effects of a contoured articular prosthetic device on tibiofemoral peak contact pressure: a biomechanical studyKnee Surgery, Sports Traumatology, Arthroscopy, 2007
- The Effect of Angled Osteochondral Grafting on Contact PressureThe American Journal of Sports Medicine, 2006
- Measuring contact area, force, and pressure for bioengineering applications: Using Fuji Film and TekScan systemsMedical Engineering & Physics, 2005
- Arthroscopic treatment of osteochondral lesions of the talusThe Journal of Bone and Joint Surgery. British volume, 2003
- Comparison of biomechanical and biochemical properties of cartilage from human knee and ankle pairsJournal of Orthopaedic Research, 2000
- A system for grading articular cartilage lesions at arthroscopyThe American Journal of Sports Medicine, 1989
- Operative Therapie der fibularen KapselbandrupturSportverletzung · Sportschaden, 1989