Abstract
A multimode control strategy for a synchronous buck converter operating over a wide load range, is presented. For heavy loads, the converter runs in fixed-frequency continuous conduction mode (CCM). At light loads, it enters discontinuous conduction mode (DCM) with synchronous rectification. At still lighter loads, synchronous rectification is disabled in DCM. At very light loads, the converter operates in variable-frequency pulse skipping mode. The synchronous rectifier (SR) timing is scheduled as a function of the load current, enabling appropriate transition among the modes. An on-line adaptive algorithm to optimize the SR timing, based on power loss minimization, is presented. This control strategy is particularly well suited for a digital controller implementation, since it uses sophisticated computations, while not requiring high analog-to-digital conversion rates.Keywords
This publication has 8 references indexed in Scilit:
- Architecture and IC implementation of a digital VRM controllerIEEE Transactions on Power Electronics, 2003
- Quantization resolution and limit cycling in digitally controlled PWM convertersIEEE Transactions on Power Electronics, 2003
- Dynamic maximum power point tracker for photovoltaic applications2002
- Synchronous rectification with adaptive timing control2002
- Optimization of power electronic systems using ripple correlation control: a dynamic programming approach2002
- Analysis and design of multivariable extremum seeking2002
- Stability of extremum seeking feedback for general nonlinear dynamic systemsAutomatica, 2000
- On the application of multi-parameter extremum seeking control2000