Dual Mobility Cemented Cups Have Low Dislocation Rates in THA Revisions
Authors:
- Mickaël RoparsMRMickaël Ropars
- François GaucherFGFrançois Gaucher
- Thierry MussetTMThierry Musset
- Olivier ChaixOCOlivier Chaix
- 1 February 2008
- journal article
- research article
- Published by Wolters Kluwer Health in Clinical Orthopaedics and Related Research
- Vol. 466 (2) , 389-395
Abstract
Esigned to improve prosthetic stability (polyethylene head ≥ 40 mm diameter) without increasing loosening rates by reducing wear and limiting impingement (rotation range of 108°). We implanted 88 cemented dual mobility cups for THA revisions in 82 patients at high risk of dislocation. Average patient age was 72 years (range, 65-86 years). Eighty-five of the 88 hips were reviewed at 2 to 5 years followup. One patient (1.1%) had a traumatic dislocation at 2 years postoperatively. Two patients (2.3%) had asymptomatic early loosening and three patients (3.5%) had localized radiographic lucencies. These results confirm those with press-fit dual mobility cups suggesting a low dislocation rate at 5 years and a cup survival of 94.6%. At middle term followup, cemented dual mobility cup achieved better results than constrained cups in cases at risk of dislocation and recurrent loosening. Level of Evidence: Level IV, therapeutic study. See the Guidelines for Authors for a complete description of levels of evidence....Keywords
This publication has 39 references indexed in Scilit:
- Antibiotic cements in articular prostheses: current orthopaedic conceptsInternational Journal of Antimicrobial Agents, 2006
- Large Diameter Femoral Heads on Highly Cross-linked PolyethyleneClinical Orthopaedics and Related Research, 2006
- An Analysis of the Risk of Hip Dislocation with a Contemporary Total Joint RegistryClinical Orthopaedics and Related Research, 2006
- A Constrained Device with Increased Range of Motion Prevents Early DislocationClinical Orthopaedics and Related Research, 2006
- The Long-term Outcome of 755 Consecutive Constrained Acetabular Components in Total Hip ArthroplastyThe Journal of Arthroplasty, 2005
- Use of a Constrained Tripolar Acetabular Liner to Treat Intraoperative Instability and Postoperative Dislocation after Total Hip ArthroplastyClinical Orthopaedics and Related Research, 2004
- Biomechanics of Large Femoral HeadsClinical Orthopaedics and Related Research, 2004
- The use of a constrained acetabular component for recurrent dislocationThe Journal of Arthroplasty, 2003
- Femoral head size is a risk factor for total hip luxationA study of 42,987 primary hip arthroplasties from the Norwegian Arthroplasty RegisterActa Orthopaedica, 2003
- Factors predisposing to dislocation after primary total hip arthroplastyThe Journal of Arthroplasty, 2002