All Integrated Lithium Niobate Standing Wave Fourier Transform Electro-Optic Spectrometer
- 13 August 2018
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Journal of Lightwave Technology
- Vol. 36 (20) , 4900-4907
Abstract
In a standard stationary wave Fourier-transform spectrometer, a static interferogram obtained in a single-mode channel waveguide is sampled by scattering centers that are regularly spaced on top of a channel waveguide. Each scattering center is placed right below a pixel, so that the sampling step is limited by the pixel pitch to avoid crosstalk. For micron-size pixels, this implies under-sampling of the fringes, and therefore, a reduced spectral etendue. In this paper, we propose to overcome this subsampling limitation by using the electro-optical properties of lithium niobate. An integrated optic inversed Y-junction finished by a mirror is used to inject in the single waveguide output two waves characterized by an optical phase difference (OPD). The mirror reflection induces a static interferogram with an OPD null at the mirror (interference of each incident wave with its own reflection) and a dynamic interferogram coming from the interference between the one wave from one arm of the Y-junction and the wave from the other arm, after being reflected by the mirror. The dynamic feature is observed by the integration of an electro-optic phase modulator set on the two arms of the reversed Y-junction inputs. Using moderate control voltages (<;100 V), a dynamic wideband fringe wave packet is shifted on several fringe periods under the sampling centers fabricated on the surface of the single waveguide output. We show that this solution can compensate the subsampling related to their large spacing and rebuild a complete interferogram, sufficiently sampled with a small acquisition time, thanks to the electro-optical performances of lithium niobate modulators. Moreover, we show that an equivalent long distance fringe scan can be obtained by superimposing the different fragments of the wideband spectrum seen by each individual sampling center for the same voltage scan. This paper opens the way to high resolution, large spectral etendue compact Fourier-transform spectrometers, where external optical path delay scan can be replaced by the internal phase-modulation using electro-optic properties of lithium niobate or similar materials.Keywords
Funding Information
- LabEx FOCUS (ANR-11-LABX-0013)
This publication has 24 references indexed in Scilit:
- Silicon and silicon nitride photonic circuits for spectroscopic sensing on-a-chip [Invited]Photonics Research, 2015
- Towards femtosecond laser written arrayed waveguide gratingsOptics Express, 2015
- Comparison of AWGs and Echelle Gratings for Wavelength Division Multiplexing on Silicon-on-InsulatorIEEE Photonics Journal, 2014
- First Results in Near and Mid IR Lithium Niobate-Based Integrated Optics Interferometer Based on SWIFTS-Lippmann ConceptJournal of Lightwave Technology, 2014
- Silicon-based heterogeneous photonic integrated circuits for the mid-infraredOptical Materials Express, 2013
- A multiplexed fiber Bragg grating sensor for simultaneous salinity and temperature measurementJournal of Applied Physics, 2008
- Wavelength-scale stationary-wave integrated Fourier-transform spectrometryNature Photonics, 2007
- Light Localizations in Photonic Crystal Line Defect WaveguidesIEEE Journal of Selected Topics in Quantum Electronics, 2004
- Fast algorithms for discrete polynomial transforms on arbitrary gridsLinear Algebra and its Applications, 2003
- Multiplexing fiber bragg grating sensorsFiber and Integrated Optics, 1991