Scan pattern optimization for uniform proton beam scanning
- 2 July 2009
- journal article
- Published by Wiley in Medical Physics
- Vol. 36 (8) , 3560-3567
Abstract
Magnetic beam scanning allows one to spread proton beam over the desired radiation field area, improving beam utilization and conformity to the target area. This article discusses generic scan forms for generating uniform circular and rectangular fields and establishes criteria that can be applied to optimize selected scan patterns. During construction of the Midwest Proton Radiotherapy Institute (MPRI), Indiana University developed a magnetically scanned beam spreading system for the 3 m long gantry nozzle. Based on the commissioning experience, criteria for optimizing the scan patterns were derived. A numerical integration model was used to perform initial optimization of the resulting dose distribution. The selected scan patterns were then experimentally validated via test irradiation of Gafchromic films. Generic spiral and linear scan forms are proposed capable of delivering uniform circular and rectangular fields in continuous scanning mode. The test irradiations performed indicate that dose uniformity is within +/- 3% for both scan forms and that penumbra of the uncollimated field can approach the radius of the pristine beam spot. A well designed uniform scanning system can have a large library of uniform circular and rectangular fields of different sizes, which would increase beam utilization and minimize out-of-field dose to the patient.Keywords
This publication has 14 references indexed in Scilit:
- Clinical characterization of a proton beam continuous uniform scanning system with dose layer stackingMedical Physics, 2008
- Neutron dose in scattered and scanned proton beams: In regard to Eric J. Hall (Int J Radiat Oncol Biol Phys 2006;65:1–7)International Journal of Radiation Oncology - Biology - Physics (IJROBP), 2006
- Intensity-modulated radiation therapy, protons, and the risk of second cancersInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2006
- Ridge filter design for proton therapy at Hyogo Ion Beam Medical CenterPhysics in Medicine & Biology, 2003
- Physical specifications of clinical proton beams from a synchrotronMedical Physics, 1996
- The 200‐MeV proton therapy project at the Paul Scherrer Institute: Conceptual design and practical realizationMedical Physics, 1995
- Instrumentation for treatment of cancer using proton and light-ion beamsReview of Scientific Instruments, 1993
- Magnetic scanning system for heavy ion therapyNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1993
- Wobbler facility for biomedical experimentsMedical Physics, 1987
- Flattening of proton dose distributions for large‐field radiotherapyMedical Physics, 1977