Keeping safe. Continuous glucose monitoring (CGM) in persons with Type 1 diabetes and impaired awareness of hypoglycaemia: a qualitative study
- 14 August 2017
- journal article
- research article
- Published by Wiley in Diabetic Medicine
- Vol. 34 (10) , 1470-1476
Abstract
Aim: To further our understanding of individual use and experience of continuous glucose monitoring (CGM) in adults with Type 1 diabetes and impaired awareness of hypoglycaemia, we conducted a qualitative study supplementary to a randomized controlled trial, using semi‐structured interviews.Methods: Twenty‐three participants of the IN CONTROL trial were interviewed within 4 weeks after the last study visit. The interview centred around experiences of CGM, taking into account the person's expectations prior to the trial. The interview was semi‐structured, using open‐ended questions and, if needed, prompts were offered to elicit further responses. Using thematic analysis, the interview transcripts were coded independently by three members of the research team. The consolidated criteria for reporting qualitative research (COREQ) were followed.Results: Overall, CGM was experienced as helpful in gaining more insight into glucose variability, and temporarily improved sense of control, reduced distress and made participants less dependent on others. However, some participants experienced confrontation with CGM output as intrusive, while some reported frustration due to failing technique and difficulty trusting the device. Participants reported active and passive self‐management behaviours mirroring individual differences in attitudes and coping styles.Conclusions: In adults with Type 1 diabetes at risk of recurrent hypoglycaemia due to impaired awareness of hypoglycaemia, CGM use enhances a sense of control and safety for most, but not all. Future studies should further explore differential use of CGM in this population in the context of active and passive self‐management styles.Keywords
Funding Information
- Eli Lilly and Company
- Sanofi
This publication has 23 references indexed in Scilit:
- Effect of Sensor-Augmented Insulin Pump Therapy and Automated Insulin Suspension vs Standard Insulin Pump Therapy on Hypoglycemia in Patients With Type 1 DiabetesJAMA, 2013
- Impact of continuous glucose monitoring on diabetes management and marital relationships of adults with Type 1 diabetes and their spouses: a qualitative studyDiabetic Medicine, 2013
- Sensor-augmented pump therapy lowers HbA1c in suboptimally controlled Type 1 diabetes; a randomized controlled trialDiabetic Medicine, 2011
- Glycaemic control in type 1 diabetes during real time continuous glucose monitoring compared with self monitoring of blood glucose: meta-analysis of randomised controlled trials using individual patient dataBMJ, 2011
- Psychosocial factors associated with use of continuous glucose monitoringDiabetic Medicine, 2010
- Quality-of-Life Measures in Children and Adults With Type 1 DiabetesDiabetes Care, 2010
- Consolidated criteria for reporting qualitative research (COREQ): a 32-item checklist for interviews and focus groupsInternational Journal for Quality in Health Care, 2007
- Using thematic analysis in psychologyQualitative Research in Psychology, 2006
- Evaluation of qualitative research studiesEvidence-Based Nursing, 2003
- Hypoglycaemia: The limiting factor in the glycaemic management of Type I and Type II Diabetes*Diabetologia, 2002