Quantitative analysis of metal artefacts of dental implant in CBCT image by correlation analysis to micro-CT: A microstructural study
- 1 March 2021
- journal article
- research article
- Published by Oxford University Press (OUP) in Dentomaxillofacial Radiology
- Vol. 50 (3) , 20200365
Abstract
Objectives: Quantification of dental implant metal artefacts in CBCT images using correlation analysis of trabecular microstructural parameters from CBCT and micro-CT, and analysis of the effect of varying the angular position of the subject. Methods: Polyurethane synthetic bone blocks were first scanned without implants by micro-CT and CBCT. Two dental implants were then placed parallel in the bone blocks and these specimens were scanned by CBCT with different alpha angles. Three volumes of interest (VOI) were set for further analysis. Six microstructural parameters were measured: trabecular thickness (TbTh), trabecular spacing (ThSp), bone volume per total volume (BV/TV), bone surface per total volume (BS/TV), connectivity density (CD) andfractal dimension (FD). Micro-CT measurements were used as a gold standard for CBCT. Spearman correlation coefficients for each microstructural parameter from CBCT and micro-CT were calculated and compared using Steiger’s Z test. Results: Without the implants, in VOI1, the Spearman correlation coefficients of TbTh, TbSp, BV/TV, BS/TV, CD and FD were 0.599, 0.76, 0.552, 0.566, 0.664 and 0.607, respectively. With the implants, the correlation coefficients decreased sharply in VOI1. As the alpha angle increased from zero to 90°, the correlation coefficients increased and became significant. Similar results appeared in VOI2. In contrast, in VOI3, the correlation coefficient decreased as the alpha angle increased. Conclusions: Metal artefacts were successfully quantified using microstructural parameters in terms of the image quality of the CBCT. Changes in alpha angle affected the quality of the CBCT image.Keywords
This publication has 39 references indexed in Scilit:
- Efficacy of a cone beam computed tomography metal artifact reduction algorithm for the detection of peri-implant fenestrations and dehiscencesOral Surgery, Oral Medicine, Oral Pathology and Oral Radiology, 2016
- Assessment of metal artefact reduction around dental titanium implants in cone beam CTDentomaxillofacial Radiology, 2014
- Artifacts Interfering with Interpretation of Cone Beam Computed Tomography ImagesDental Clinics of North America, 2014
- Artefacts in CBCT: a reviewDentomaxillofacial Radiology, 2011
- On cone‐beam computed tomography artifacts induced by titanium implantsClinical Oral Implants Research, 2009
- A novel forward projection-based metal artifact reduction method for flat-detector computed tomographyPhysics in Medicine & Biology, 2009
- A post‐reconstruction method to correct cupping artifacts in cone beam breast computed tomographyMedical Physics, 2007
- Reducing metal artifacts in cone-beam CT images by preprocessing projection dataInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2007
- Image artifact in dental cone-beam CTOral Surgery Oral Medicine Oral Pathology Oral Radiology and Endodontology, 2006
- Measured X-Ray Spectra from 25 to 110 kVp for a Typical Diagnostic UnitRadiology, 1972