Detection of significant vision conditions in children using QuickSee wavefront autorefractor
Open Access
- 19 March 2024
- journal article
- research article
- Published by Springer Nature in Ophthalmic and Physiological Optics
- Vol. 44 (3) , 501-513
Abstract
Purpose: This study evaluated the ability of QuickSee to detect children at risk for significant vision conditions (significant refractive error [RE], amblyopia and strabismus). Methods: Non‐cycloplegic refraction (using QuickSee without and with +2 dioptre (D) fogging lenses) and unaided binocular near visual acuity (VA) were measured in 4‐ to 12‐year‐old children. Eye examination findings (VA, cover testing and cycloplegic retinoscopy) were used to determine the presence of vision conditions. QuickSee performance was summarised by area under the receiver operating characteristic curve (AUC), sensitivity and specificity for various levels of RE. QuickSee referral criteria for each vision condition were chosen to maximise sensitivity at a specificity of approximately 85%–90%. Sensitivity and specificity to detect vision conditions were calculated using multiple criteria. Logistic regression was used to evaluate the benefit of adding near VA (6/12 or worse) for detecting hyperopia. A paired t ‐test compared QuickSee without and with fogging lenses. Results: The mean age was 8.2 (±2.5) years ( n = 174). RE ranged up to 9.25 D myopia, 8 D hyperopia, 5.25 D astigmatism and 3.5 D anisometropia. The testability of the QuickSee was 94.3%. AUC was ≥0.92 (excellent) for each level of RE. For the detection of any RE, sensitivity and specificity were 84.2% and 87.3%, respectively, using modified Orinda criteria and 94.5% and 78.2%, respectively, using the American Academy for Pediatric Ophthalmology and Strabismus (AAPOS) guidelines. For the detection of any significant vision condition, the sensitivity and specificity of QuickSee were 81.1% and 87.9%, respectively, using modified Orinda criteria and 93% and 78.6%, respectively, using AAPOS criteria. There was no significant benefit of adding near VA to QuickSee for the detection of hyperopia ≥+2.00 ( p = 0.34). There was no significant difference between QuickSee measurements of hyperopic refractive error with and without fogging lenses (difference = −0.09 D; p = 0.51). Conclusions: QuickSee had high discriminatory power for detecting children with hyperopia, myopia, astigmatism, anisometropia, any significant refractive error or any significant vision condition.Keywords
Funding Information
- Ohio Lions Eye Research Foundation
This publication has 35 references indexed in Scilit:
- Effectiveness of the Spot Vision Screener using updated 2021 AAPOS guidelinesJournal of American Association for Pediatric Ophthalmology and Strabismus, 2023
- AAPOS uniform guidelines for instrument-based pediatric vision screen validation 2021Journal of American Association for Pediatric Ophthalmology and Strabismus, 2022
- Refractive Error Findings in Students Who Failed School-based Vision ScreeningOphthalmic Epidemiology, 2021
- Receipt of Corrective Lenses and Academic Performance of Low-Income StudentsAcademic Pediatrics, 2020
- Evaluation of the Spot Vision Screener for children with limited access to ocular health careJournal of American Association for Pediatric Ophthalmology and Strabismus, 2019
- Visual Function of Moderately Hyperopic 4- and 5-Year-Old Children in the Vision in Preschoolers – Hyperopia in Preschoolers StudyAmerican Journal of Ophthalmology, 2016
- Parent, Teacher, and Student Perspectives on How Corrective Lenses Improve Child Wellbeing and School FunctionMaternal and Child Health Journal, 2015
- AmblyopiaThe Lancet, 2006
- Comparison of preschool vision screening tests as administered by licensed eye care professionals in the vision in preschoolers study*1Ophthalmology, 2004
- Slopes of a Receiver Operating Characteristic Curve and Likelihood Ratios for a Diagnostic TestAmerican Journal of Epidemiology, 1998