Determination of glutathione in blood via capillary electrophoresis with pH‐mediated stacking
- 29 July 2022
- journal article
- research article
- Published by Wiley in Electrophoresis
- Vol. 43 (18-19) , 1859-1870
Abstract
A new approach has been developed for the direct determination of reduced (glutathione [GSH]) and oxidized (glutathione disulfide [GSSG]) GSH in whole blood by means of capillary electrophoresis. Its features include GSH‐stabilizing sample preparation, the use of an internal standard, and pH‐mediated stacking. Blood stabilized with acid citrate and K3EDTA was treated with acetonitrile with N‐ethylmaleimide, and then the analytes were extracted with diethyl ether. The total analysis time was 8 min using a 50‐µm (i.d.) by 32.5‐cm (eff. length) silica capillary. The background electrolyte was 0.075‐M citrate Na pH 5.8 with 200‐µM cetyltrimethylammonium bromide and 5‐µM sodium dodecyl sulfate, and the separation voltage was −14 kV. The quantification limit (S/N = 15) of the method was 1.5 µM for GSSG. The accuracy levels of GSH and GSSG analysis were 104% and 103%, respectively, and between‐run precision levels were 2.6% and 3.2%, respectively. Analysis of blood samples from healthy volunteers (N = 24) showed that the levels of GSH and GSSG and the GSH/GSSG ratio in the whole blood were 1.05 ± 0.14 mM, 3.9 ± 1.25 µM, and 256 ± 94, respectively. Thus, the presented approach can be used in clinical and laboratory practice.Keywords
Funding Information
- Russian Foundation for Basic Research (20‐04‐60251∖20)
This publication has 44 references indexed in Scilit:
- A Fast Response Highly Selective Probe for the Detection of Glutathione in Human Blood PlasmaSensors, 2012
- Methods for the Determination of Plasma or Tissue Glutathione Levels2012
- A new HPLC method for the simultaneous determination of ascorbic acid and aminothiols in human plasma and erythrocytes using electrochemical detectionTalanta, 2011
- HPLC analysis of human erythrocytic glutathione forms using OPA and N-acetyl-cysteine ethyl ester: Evidence for nitrite-induced GSH oxidation to GSSGJournal of Chromatography B, 2009
- Differential Rates of Glutathione Oxidation for Assessment of Cellular Redox Status and Antioxidant Capacity by Capillary Electrophoresis-Mass Spectrometry: An Elusive Biomarker of Oxidative StressAnalytical Chemistry, 2009
- Glutathione: Overview of its protective roles, measurement, and biosynthesisMolecular Aspects of Medicine, 2009
- Determination of reduced and oxidized glutathione in biological samples using liquid chromatography with fluorimetric detectionJournal of Pharmaceutical and Biomedical Analysis, 2007
- On‐line sample concentration techniques in capillary electrophoresis: Velocity gradient techniques and sample concentration techniques for biomoleculesElectrophoresis, 2004
- Direct determination of glutathione in human blood by micellar electrokinetic chromatography: Simultaneous determination of lipoamide and lipoic acidElectrophoresis, 1996
- Determination of Glutathione1955