Enhancing DFIG wind turbine during three‐phase fault using parallel interleaved converters and dynamic resistor
Open Access
- 27 June 2016
- journal article
- research article
- Published by Institution of Engineering and Technology (IET) in IET Renewable Power Generation
- Vol. 10 (8) , 1211-1219
Abstract
Transient operations are very crucial for high power insulated‐gate bipolar transistor modules, because high current and voltage are applied during this period for several microseconds. Therefore, the ability for doubly fed induction generator (DFIG) variable speed wind turbine power converters to withstand abnormal conditions is strictly imperative in order to achieve its lifetime specifications and also fulfil the grid codes. This study presents a new control scheme for DFIG wind turbine having parallel interleaved converters (PIC) configuration and a series dynamic braking resistor (SDBR) connected at its stator side. Interleaving the wind turbine converters in parallel configuration could help to increase the current capability, while the SDBR helps in post fault recovery of the wind turbine. The coordinated control analysis of the scheme was implemented in power system computer aided design and electromagnetic transient including DC simulation environment for a severe three‐phase to ground fault. Results obtained were compared with the conventional DC chopper and crowbar rotor circuit protection scheme for the wind turbine. A better performance of the wind turbine variables were achieved using the proposed control scheme of the PIC and SDBR because the space vector modulation of the PIC results in maximum value of the change in common mode voltage, leading to improved switched output voltage of the voltage source converter leg.Keywords
This publication has 32 references indexed in Scilit:
- Minimum-Threshold Crowbar for a Fault-Ride-Through Grid-Code-Compliant DFIG Wind TurbineIEEE Transactions on Energy Conversion, 2010
- STATCOM-Based Indirect Torque Control of Induction Machines During Voltage Recovery After Grid FaultsIEEE Transactions on Power Electronics, 2009
- Dynamic response of doubly fed induction generator variable speed wind turbine under faultElectric Power Systems Research, 2008
- Transient Stability Augmentation of Power System Including Wind Farms by Using ECSIEEE Transactions on Power Systems, 2008
- An Improved Control Strategy of Limiting the DC-Link Voltage Fluctuation for a Doubly Fed Induction Wind GeneratorIEEE Transactions on Power Electronics, 2008
- Dynamic Behaviour of DFIG-Based Wind Turbines During Grid FaultsIEEJ Transactions on Industry Applications, 2008
- Fundamental time–domain wind turbine models for wind power studiesRenewable Energy, 2007
- Double-fed induction generator control for variable speed wind power generationElectric Power Systems Research, 2006
- Transient stability of DFIG wind turbines at an external short‐circuit faultWind Energy, 2005
- Control scheme studies of voltage source type superconducting magnetic energy storage (SMES) under asymmetrical voltageIEEE Transactions on Applied Superconductivity, 2002