Magnetic targeting to enhance microbubble delivery in an occluded microarterial bifurcation
Authors:
Open Access
- 5 September 2017
- journal article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 62 (18) , 7451-7470
Abstract
Ultrasound and microbubbles have been shown to accelerate the breakdown of blood clots both in vitro and in vivo. Clinical translation of this technology is still limited, however, in part by inefficient microbubble delivery to the thrombus. This study examines the obstacles to delivery posed by fluid dynamic conditions in occluded vasculature and investigates whether magnetic targeting can improve microbubble delivery. A 2D computational fluid dynamic model of a fully occluded Y-shaped microarterial bifurcation was developed to determine: (i) the fluid dynamic field in the vessel with inlet velocities from 1-100 mm s-1 (corresponding to Reynolds numbers 0.25-25); (ii) the transport dynamics of fibrinolytic drugs; and (iii) the flow behavior of microbubbles with diameters in the clinically-relevant range (0.6-5 µm). In vitro experiments were carried out in a custom-built microfluidic device. The flow field was characterized using tracer particles, and fibrinolytic drug transport was assessed using fluorescence microscopy. Lipid-shelled magnetic microbubbles were fluorescently labelled to determine their spatial distribution within the microvascular model. In both the simulations and experiments, the formation of laminar vortices and an abrupt reduction of fluid velocity were observed in the occluded branch of the bifurcation, severely limiting drug transport towards the occlusion. In the absence of a magnetic field, no microbubbles reached the occlusion, remaining trapped in the first vortex, within 350 µm from the bifurcation center. The number of microbubbles trapped within the vortex decreased as the inlet velocity increased, but was independent of microbubble size. Application of a magnetic field (magnetic flux density of 76 mT, magnetic flux density gradient of 10.90 T m-1 at the centre of the bifurcation) enabled delivery of microbubbles to the occlusion and the number of microbubbles delivered increased with bubble size and with decreasing inlet velocity.Keywords
Funding Information
- EPSRC (EP/I021795/1)
- RCUK (EP/G036861/1)
This publication has 49 references indexed in Scilit:
- Facile and cost-effective production of microscale PDMS architectures using a combined micromilling-replica moulding (μMi-REM) techniqueBiomedical Microdevices, 2016
- Halbach arrays consisting of cubic elements optimised for high field gradients in magnetic drug targeting applicationsPhysics in Medicine & Biology, 2015
- Spatiotemporal dynamics of doxorubicin elution from embolic beads within a microfluidic networkJournal of Controlled Release, 2015
- Threshold of Microvascular Occlusion: Injury Size Defines the Thrombosis ScenarioBiophysical Journal, 2015
- Clinical Policy: Use of Intravenous tPA for the Management of Acute Ischemic Stroke in the Emergency DepartmentAnnals of Emergency Medicine, 2013
- Influences of Microbubble Diameter and Ultrasonic Parameters on In Vitro Sonothrombolysis EfficacyJournal of Vascular and Interventional Radiology, 2012
- Microbubbles Improve Sonothrombolysis In Vitro and Decrease Hemorrhage In Vivo in a Rabbit Stroke ModelInvestigative Radiology, 2011
- A Pilot Randomized Clinical Safety Study of Sonothrombolysis Augmentation With Ultrasound-Activated Perflutren-Lipid Microspheres for Acute Ischemic StrokeStroke, 2008
- Prioritizing interventions to improve rates of thrombolysis for ischemic strokeNeurology, 2005
- Eddy-Current Method for Measuring the Resistivity of MetalsJournal of Applied Physics, 1959