Are therapeutic ultrasound units a potential vector for nosocomial infection?
- 19 May 2006
- journal article
- research article
- Published by Wiley in Physiotherapy Research International
- Vol. 11 (2) , 61-71
Abstract
Background and Purpose. Nosocomial infections present a widespread problem in today's healthcare environment, with a significant number of patients acquiring an infection annually. With the contemporary transition of immunocompromised and high‐risk patients to community‐based care, therapeutic ultrasound has the potential to be a vector of infection in the physiotherapy setting. The purpose of the present study was to determine the degree of contamination on therapeutic ultrasound transducer heads and ultrasound gel after routine clinical use, and to evaluate the efficacy of recommended infection control procedures. Method. The study consisted of two phases. Using a prospective cross‐sectional design, microbiological cultures were obtained from 44 transducer heads and 43 gels. Subjects were drawn from a variety of physiotherapy practice settings. All samples containing more than five colony forming units per cm2 were considered contaminated. Following these measurements, a repeated‐measures design was used to re‐evaluate the 44 transducer heads for the amount and type of bacteria present after cleaning with a 70% alcohol wipe. Results. Twenty‐seven per cent of transducer heads and 28% of gels were contaminated. Transducer heads showed fairly low levels of contamination across the sample, with the majority of organisms isolated found in normal skin and environmental flora. Gels were heavily contaminated with opportunistic and potentially pathogenic organisms, including Stenotrophomonas maltophilia, Staphylococcus aureus, Acinetobacter baumannii and Rhodotorula mucilaginosa. No multi‐resistant organisms were identified. Cleaning with 70% alcohol significantly reduced the level of contamination on transducer heads (p < 0.01). Conclusions. Therapeutic ultrasound equipment is a potential vector for nosocomial infection in physiotherapy patients. The risk of infection from transducer heads can be effectively removed by cleaning with 70% alcohol between patients. Further research into possible strategies to reduce the risk of infection from ultrasound gels is needed. Copyright © 2006 John Wiley & Sons, Ltd.Keywords
This publication has 16 references indexed in Scilit:
- Therapeutic Ultrasound: Clinician Usage and Perception of EfficacyHong Kong Physiotherapy Journal, 2003
- Stethoscope: a friend or an enemy?Sao Paulo Medical Journal, 2002
- The stethoscope in the emergency department: a vector of infection?Epidemiology and Infection, 2000
- Interferential therapy machines as possible vehicles for cross-infectionJournal of Hospital Infection, 2000
- Bacterial Contamination of Hospital Physicians' StethoscopesInfection Control & Hospital Epidemiology, 1999
- Stethoscopes and otoscopes--a potential vector of infection?Family Practice, 1997
- The increasing significance of outbreaks of Acinetobacter spp.: the need for control and new agentsJournal of Hospital Infection, 1995
- A Survey of Electrotherapeutic Modalities: Ownership and Use in the NHS in EnglandPhysiotherapy, 1995
- Stethoscope contamination in the neonatal intensive care unitJournal of Hospital Infection, 1995
- Ultrasound in physiotherapy in the United Kingdom: Results of a questionnairePhysiotherapy Practice, 1988