Pentacam sensitivity and specificity in detecting occludable angles
- 13 January 2012
- journal article
- research article
- Published by SAGE Publications in European Journal of Ophthalmology
- Vol. 22 (5) , 701-708
Abstract
Purpose: To assess the sensitivity and specificity of Pentacam measurements in detection of occludable angles and to provide cutoff values. Methods: Observational, single-center, cross-sectional study on 64 Caucasian eyes: 28 (43.7%) primary narrow angles or primary angle-closure glaucoma, and 36 (56.2%) controls: all subjects were evaluated and classified by gonioscopy (Shaffer classification). The following measurements have been considered: superior and inferior anterior chamber angle (ACA), temporal and nasal ACA, anterior chamber depth (ACD) using 5 value representation (central, superior, inferior, nasal, temporal), and anterior chamber volume (ACV). Validity of Pentacam parameters to detect patients in Shaffer 0 or I class was assessed by receiver operating characteristic (ROC) curves analysis; cutoffs were chosen as to maximize sensitivity and specificity. Results: All the considered Pentacam measures were statistically different between the 2 groups (p3) allowed correct classification of narrow angles. Conclusions: The study pointed out a high power of Pentacam AVA, ACV, and ACD in detecting occludable angles. Pentacam is simple to use, reliable, and noncontact, provides parameters in a short period, and represents a possible screening tool.Keywords
This publication has 22 references indexed in Scilit:
- Central Corneal Thickness, Anterior Chamber Depth, and Pupil Diameter Measurements Using Visante OCT, Orbscan, and PentacamJournal of Refractive Surgery, 2010
- Potential of the Pentacam in Screening for Primary Angle Closure and Primary Angle Closure SuspectJournal of Glaucoma, 2009
- Prevalence and Determinants of Angle Closure in Central Sri Lanka: The Kandy Eye StudyOphthalmology, 2009
- Anterior segment biometry with the Pentacam: Comprehensive assessment of repeatability of automated measurementsJournal of Cataract & Refractive Surgery, 2008
- Incidence of occludable angles in a high-risk Mongolian populationBritish Journal of Ophthalmology, 2007
- Ethnic differences in primary angle-closure glaucomaCurrent Opinion in Ophthalmology, 2006
- The number of people with glaucoma worldwide in 2010 and 2020British Journal of Ophthalmology, 2006
- Can we prevent angle-closure glaucoma?Eye, 2005
- Epidemiology of angle-closure glaucomaOphthalmology, 2000
- Bedford glaucoma survey.BMJ, 1968