Detection of tissue harmonic motion induced by ultrasonic radiation force using pulse-echo ultrasound and kalman filter
Authors:
- 26 February 2007
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 54 (2) , 290-300
Abstract
A method using pulse echo ultrasound and the Kalman filter is developed for detecting submicron harmonic motion induced by ultrasonic radiation force. The method estimates the amplitude and phase of the motion at desired locations within a tissue region with high sensitivity. The harmonic motion generated by the ultrasound radiation force is expressed as extremely small oscillatory Doppler frequency shifts in the fast time (A-line) of ultrasound echoes, which are difficult to estimate. In slow time (repetitive ultrasound echoes) of the echoes, the motion also is presented as oscillatory phase shifts, from which the amplitude and phase of the harmonic motion can be estimated with the least mean squared error by Kalman filter. This technique can be used to estimate the traveling speed of a harmonic shear wave by tracking its phase changes during propagation. The shear wave propagation speed can be used to solve for the elasticity and viscosity of tissue as reported in our earlier study. Validation and in vitro experiments indicate that the method provides excellent estimations for very small (submicron) harmonic vibrations and has potential for noninvasive and quantitative stiffness measurements of tissues such as artery.Keywords
This publication has 20 references indexed in Scilit:
- Comparison of stress field forming methods for vibro-acoustographyIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 2004
- Shear wave elasticity imaging: a new ultrasonic technology of medical diagnosticsUltrasound in Medicine & Biology, 1998
- An asynchronous multiuser CDMA detector based on the Kalman filterIEEE Journal on Selected Areas in Communications, 1998
- Time domain Doppler estimators of the amplitude of vibrating targetsThe Journal of the Acoustical Society of America, 1992
- Elastography: A quantitative method for imaging the elasticity of biological tissuesUltrasonic Imaging, 1991
- Real-Time Two-Dimensional Blood Flow Imaging Using an Autocorrelation Technique1985
- A Kalman Filter Approach to Precision GPS GeodesyNAVIGATION: Journal of the Institute of Navigation, 1983
- Integrated Navigation Systems and Kalman Filtering: A PerspectiveNAVIGATION: Journal of the Institute of Navigation, 1972
- Least-squares estimation: from Gauss to KalmanIEEE Spectrum, 1970
- A New Approach to Linear Filtering and Prediction ProblemsJournal of Basic Engineering, 1960