Can a Glove-Coach Technology Significantly Increase the Efficacy of Cardiopulmonary Resuscitation on Non-healthcare Professionals? A Controlled Trial
Authors:
Open Access
- 9 December 2021
- journal article
- research article
- Published by Frontiers Media SA in Frontiers in Cardiovascular Medicine
- Vol. 8, 685988
Abstract
Introduction: Cardiovascular accidents are the world's leading cause of death. A good quality cardiopulmonary resuscitation (CPR) can reduce cardiac arrest-associated mortality. This study aims to test the coaching system of a wearable glove, providing instructions during out-of-hospital CPR.Materials and Methods: We performed a single-blind, controlled trial to test non-healthcare professionals during a simulated CPR performed on an electronic mannequin. The no-glove group was the control. The primary outcome was to compare the accuracy of depth and frequency of two simulated CPR sessions. Secondary outcomes were to compare the decay of CPR performance and the percentage of the duration of accurate CPR.Results: About 130 volunteers were allocated to 1:1 ratio in both groups; mean age was 36 ± 15 years (min–max 21–64) and 62 (48%) were men; 600 chest compressions were performed, and 571 chest compressions were analyzed. The mean frequency in the glove group was 117.67 vs. 103.02 rpm in the control group (p < 0.001). The appropriate rate cycle was 92.4% in the glove group vs. 71% in the control group, with a difference of 21.4% (p < 0.001). Mean compression depth in the glove group was 52.11 vs. 55.17 mm in the control group (p < 0.001). A mean reduction of compression depth over time of 5.3 mm/min was observed in the control group vs. 0.83 mm/min of reduction in the glove group.Conclusion: Visual and acoustic feedbacks provided through the utilization of the glove's coaching system were useful for non-healthcare professionals' CPR performance.Keywords
This publication has 34 references indexed in Scilit:
- Effect of Rescue Breathing During Cardiopulmonary Resuscitation on Lung Function After Restoration of Spontaneous Circulation in a Porcine Model of Prolonged Cardiac Arrest*Critical Care Medicine, 2013
- Can lightweight rescuers adequately perform CPR according to 2010 resuscitation guideline requirements?Emergency Medicine Journal, 2012
- An audiovisual feedback device for compression depth, rate and complete chest recoil can improve the CPR performance of lay persons during self-training on a manikinPhysiological Measurement, 2011
- The use of CPR feedback/prompt devices during training and CPR performance: A systematic reviewResuscitation, 2009
- Improving cardiopulmonary resuscitation quality and resuscitation training by combining audiovisual feedback and debriefing*Critical Care Medicine, 2008
- Quality of out-of-hospital cardiopulmonary resuscitation with real time automated feedback: A prospective interventional studyResuscitation, 2006
- Incomplete chest wall decompression: A clinical evaluation of CPR performance by trained laypersons and an assessment of alternative manual chest compression–decompression techniquesResuscitation, 2006
- Active compression–decompression cardiopulmonary resuscitation (ACD-CPR) compared with standard CPR in a manikin model — decompression force, compression rate, depth and durationResuscitation, 1997
- The Effect of Compression Duration on Hemodynamics during Mechanical High‐impulse CPRAcademic Emergency Medicine, 1994
- Influence of compression rate on initial success of resuscitation and 24 hour survival after prolonged manual cardiopulmonary resuscitation in dogs.Circulation, 1988