Comparison of established and novel purity tests for the quality control of heparin by means of a set of 177 heparin samples
- 8 September 2010
- journal article
- research article
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 399 (2) , 605-620
Abstract
The widespread occurrence of heparin contaminated with oversulfated chrondroitin sulfate (OSCS) in 2008 initiated a comprehensive revision process of the Pharmacopoeial heparin monographs and stimulated research in analytical techniques for the quality control of heparin. Here, a set of 177 heparin samples from the market in 2008 as well as pure heparin sodium spiked with defined amounts of OSCS and DS were used to evaluate established and novel methods for the quality control of heparin. Besides 1H nuclear magnetic resonance spectroscopy (NMR), the assessment included two further spectroscopic methods, i.e., attenuated total reflection-infrared spectroscopy (ATR-IR) and Raman spectroscopy, three coagulation assays, i.e., activated partial thromboplastin time (aPTT) performed with both sheep and human plasma and the prothrombin time (PT), and finally two novel purity assays, each consisting of an incubation step with heparinase I followed by either a fluorescence measurement (Inc-PolyH-assay) or by a chromogenic aXa-assay (Inc-aXa-assay). NMR was shown to allow not only sensitive detection, but also quantification of OSCS by using the peak-height method and a response factor determined by calibration. Chemometric evaluation of the NMR, ATR-IR, and Raman spectra by statistical classification techniques turned out to be best with NMR spectra concerning the detection of OSCS. The validity of the aPTT, the current EP assay, could be considerably improved by replacing the sheep plasma by human plasma. In this way, most of the contaminated heparin samples did not meet the novel potency limit of 180 IU/mg. However, also more than 50% of the uncontaminated samples had <180 IU/MG. In contrast to the aPTT, the PT specifically detects OSCS and other heparin mimetics (LOD 3%). About ten times more sensitive are both the Inc-PolyH-assay and the Inc-aXa-assay, two rapid and simple quantification assays for heparin mimetics. The determined OSCS contents of the heparin samples excellently correlated with those calculated from the NMR spectra. In conclusion, NMR proved to be the current spectroscopic method of choice. The two two-step-assays represent options to supplement NMR, especially as tests for the initial screening, since they detect any heparin mimetic without requiring special expertise for interpretation of the results.Keywords
This publication has 38 references indexed in Scilit:
- Reply to Oversulfated chondroitin sulfate is not the sole contaminant in heparinNature Biotechnology, 2010
- Broadening of 1H NMR signals in the spectra of heparin and OSCS by paramagnetic transition metal ions. The use of EDTA to sharpen the signalsJournal of Pharmaceutical and Biomedical Analysis, 2010
- Analysis of pharmaceutical heparins and potential contaminants using 1H-NMR and PAGEJournal of Pharmaceutical Sciences, 2009
- Determination of oversulfated chondroitin sulfate and dermatan sulfate impurities in heparin by capillary electrophoresisJournal of Chromatography A, 2009
- Improved impurity fingerprinting of heparin by high resolution 1H NMR spectroscopyJournal of Pharmaceutical and Biomedical Analysis, 2009
- Quantitative capillary electrophoresis determination of oversulfated chondroitin sulfate as a contaminant in heparin preparationsAnalytical Biochemistry, 2009
- Effect of Ca2+ on the 1H NMR chemical shift of the methyl signal of oversulphated chondroitin sulphate, a contaminant in heparinJournal of Pharmaceutical and Biomedical Analysis, 2009
- Determination of impurities in heparin by capillary electrophoresis using high molarity phosphate buffersJournal of Pharmaceutical and Biomedical Analysis, 2009
- Quality assessment of unfractionated heparin using 1H nuclear magnetic resonance spectroscopyJournal of Pharmaceutical and Biomedical Analysis, 2008
- Oversulfated chondroitin sulfate is a contaminant in heparin associated with adverse clinical eventsNature Biotechnology, 2008