Abstract
Relevance. Electricity supply to remote settlements in the North is carried out using autonomous power systems, which are a combination of diesel generator units. These units consume significant volumes of expensive diesel fuel. Reducing the volume of fuel consumption by using renewable energy facilities has practical relevance and demand. Aim. Evaluation of the possibility of using manual tracker units in micro-power PV-power plants operating as part of autonomous power systems in the North by performing in-kind studies. Methods. Methods of determining the efficiency of using manual and automatic tracker units for PV-power plants, and processessing experimental data. Results and conclusions. The authors have identified the indicators of increase in electricity generation before and after the introduction of tracker units. The volumes of reduction in diesel fuel consumption in an autonomous power system are calculated depending on the type of tracker unit. Recommendations for the sustainable operation of manual tracker units for micro-power PV-power plants are formed. The authors substantiated the impossibility of using manual tracker units in small and large-capacity solar energy facilities due to high labor costs. The obtained results of applied research can be used to update the existing list of technical measures to improve PV-power plants located in the North. The capital cost of manual tracker units is 70–80% less than their automatic counterparts. This type of units increases the average daily electricity generation from a PV-power plant by 17–18% provided that the orientation of the PV-panels relative to the Sun changes hourly. Based on the results of the technical and economic assessment, it was determined that in the case of introducing manual tracker units into a PV-power plant with an installed capacity of 20 kW in the village of Toyon-Aryy, an average annual saving of diesel fuel of up to 8.8 tons is achieved with a payback period of up to 11.7 years. The carbon footprint in the energy system under study is reduced in the form of a decrease in CO2 emissions to 27.7 tons per year.Keywords
This publication has 12 references indexed in Scilit:
- Contribution of weather conditions and anthropogenic activity to the variation of grain yields in the North-West of RussiaE3S Web of Conferences, 2023
- Study of Operation of Combined Power Supply System Based on Renewable Energy in Territory of Far East of Russia2021
- Autonomous renewable energy systems in Russia. Critical review of the current situationEnergy Reports, 2020
- Analysis of Solar District Cooling systems: the Effect of Heat RejectionE3S Web of Conferences, 2020
- Modeling a Solar Power Plant with Regard to Changes in Environmental ParametersPower Technology and Engineering, 2020
- Operational experience of a Solar Power Plant with a Dual-Axis Solar Tracking System in the conditions of the Southern UralsE3S Web of Conferences, 2019
- Assessment of Feasible Power Supply Options for New Projects in the Arctic Zone of the Republic of Sakha (Yakutia)2019
- Experience of solar-diesel power plant introduction in the village of Nerkha of the Irkutsk region2019
- Study of the effect of natural factors on optimal capacity of renewable energy resources2019
- Evaluation of the impact of adjusting the angle of the axis of a wind turbine rotor relative to the flow of air stream on operating parameters of a wind turbine model2017